53
Specifications
CF-4700 FFT Comparator
Controls
Power switch
Holding down 1 second causes power on. • Holding down causes forced power off.
Holding down 1 second causes power on. • Holding down causes forced power off.
Setting key
Soft keys on the lower part of LCD screen can set each function in detail.
Control key
Soft keys on the right side of LCD screen can control measurements and analyses
and can also set various conditions.
Analysis
Frequency range
1 Hz to 40 kHz
Frequency accuracy
Reading ±0.005% (±50 ppm)
Sampling Frequency
Frequency 2.56 times the frequency range (during internal sampling)
Items sampled and analyzed
Sampled
Analyzed
256
100
512
200
1024
400
2048
800
4096
1600
8192
3200
16384
6400
Overlapping
MAX, 75%, 66.7%, 50%, 25%, 0%, customized
Window function
Rectangular, Hanning, FlatTop
Time-axis waveform
processing function
1st-order, 2nd-order differential/single, double integration
Absolute value conversion, DC cancel, trend removal, smoothing
FFT realtime rate
40 kHz (internal sample: FET 16384 points)
Averaging function
• Averaging can be terminated by specifying the number of times or seconds
• A/D over cancel function
Averaging count setting
1 to 65535 times
Averaging time setting
0.1 to 999.9 seconds
Time domain
Arithmetic mean, exponential averaging
Frequency area
Arithmetic mean, exponential averaging, peak
hold, MaxOA
Amplitude domain
Histogram addition average
Trigger function
TRIG'D blinking green on screen during triggering
Trigger level (internal trigger)
−99 to 99 (unit: %), default = 25%
Hysteresis level (internal trigger)
0 to 99 (unit: %), default = 2%
Position
±8191
Mode
Free, repeat, single, one-shot
Source
CH1/external trigger input
Slope
+, −, ± (internal trigger only)
FFT operation
32-bit floating point number (IEEE single precision format)