ONLINE ELECTRONICS LTD
3015_5001_A01
Page 6 of 17
2.
SPECIFICATIONS
NOTE THAT THE SPECIFICATIONS BELOW ARE VALID FOR THE STANDARD
CONFIGURATION ONLY. REFER TO PAGE 2 OF THIS MANUAL FOR THE
CONFIGURATION INFORMATION SPECIFIC TO THE TRANSMITTER BEING USED.
GENERAL:
Lifetime in continuous mode at +20°C in air ............................................................. 5 days
Lifetime pulsing 0.4sec ON / 0.6sec OFF at +20°C in air ............................................. 9 days
Lifetime pulsing 0.4sec ON / 1.6sec OFF at +20°C in air ............................................ 17 days
Lifetime pulsing 0.4sec ON / 2.6sec OFF at +20°C in air ........................................... 25 days
Lifetime pulsing 0.4sec ON / 3.6sec OFF at +20°C in air ........................................... 31 days
Lifetime pulsing 0.4sec ON / 4.6sec OFF at +20°C in air ........................................... 37 days
Alkaline batteries ................................ 5x DURACELL INDUSTRIAL ID1300 ALKALINE D CELLS
Standard signal at 1m with OEL reference antenna at +20°C in air ........................... 624mVpp
Standard frequency ............................................................................................... 21.8Hz
Operating temperature range ......................................................................... -20 to +54°C
External pressure rating ......................................................................................... 500bar
Bump rating.............................................................................................................. 20G
Weight in air (including batteries) ................................................................................. 7kg
MATERIALS:
Housing material .................................................. ASTM B348 GRADE 5 TITANIUM Ti-6Al-4V
Endcap material ................................................................ ALLOY BRONZE CA104 EN 12163
Bleedscrew material .......................................................... 316 STAINLESS STEEL EN 1.4401
O-rings ............................................................... NBR70 (standard) / FKM936 (heavy duty)
ATEX:
Notified body number................................................................................................ 0891
Type examination number ............................................................... TRAC 09 ATEX 21218 X
Code ......................................................................................... Ex II 2 G Ex d IIB T4..T6X