ONLINE ELECTRONICS LTD
3015_5001_A01
Page 8 of 17
4.
OPERATION
Familiarise yourself with all of the rules for the safe operation of this equipment as described in
Section 3 RULES FOR SAFE OPERATION.
4.1.
TURNING ON
1.
To turn the transmitter on, fully tighten the bleed screw using a 10mm AF Allen key. Do
not use excessive torque. The transmitter takes approximately 5 seconds to turn on. Note
that the transmitter is usually shipped with a Nylon washer under the bleed screw to
prevent accidental activation during transport. This must be removed before the
transmitter can be turned on.
2.
Use an EM receiver system to confirm that the transmitter is functioning properly at the
expected pulse rate.
4.2.
TURNING OFF
1.
To turn the transmitter off, loosen the bleed screw 3 full turns using a 10mm AF Allen key.
To prevent the bleed screw being lost, or the transmitter accidentally being turned back
on, the bleed screw should be held in this position with some tape.
2.
Use an EM receiver system to confirm that the transmitter has turned off.