background image

14

Dominator Kit

Dominator Pump

MiniPress

Presscontrol

WaterSwitch

D7535, D7556, D7557

or

DM7535, D7556

or 

DP11557

or

DW7535, DW7556

13

OR

OR

OR

Installation Instructions

This quality Wall bracket has been designed to support the Onga Presscontrol or 
Onga Minipress when they are remotely mounted from the pump. Various mounting 
positions allow you to install this device thru 360 0 rotation and position the control 
panel in view and with access.

Wall Bracket kit (Presscontrol/Minipress) 

Part Number 801447

 Kit 

contents

 

1x Wall bracket

 

2x Fixing screws

Water Flow 

Direction 

Wall or post 

Water Flow 

Direction 

Wall or post 

Water Flow 

Direction 

Wall or post 

Gap

(add spacer) 

Controller

(not supplied)

Wa

(s

Screws

(supplied)

Hose Fitting

(not supplied)

House W

a

ll

Use of Mounting Bracket 

Where possible please mount Constant 
Pressure  Control Unit out of weather and 
with control panel in vertical

Bracket Mounting Options

The control device must be 
fi tted vertically as shown on 
diagram with arrow pointing  
vertical for correct and reliable 
function. Select the appropriate 
mounting hole for your chosen 
controller position.

Note: Depending upon the type of plumbing fi tting 
selected, the pressure control device may not 
be fi rmly clamped to the wall bracket. We recommend 
a spacer (not supplied) be fi tted where necessary

Summary of Contents for Dominator 11557

Page 1: ... of equipment you should contact the distributor manufacturer for the correct advice before proceeding with the installation or operation of this product For the Installation Operation and Service of Dominator Submersible Pump An earth leakage or residual current protection devide must be fitted to all instructions ...

Page 2: ... will 4 Our Team of Dealers The hand picked authorised Onga dealer network throughout Australia and worldwide are second to none We invest considerable time and resources training and supporting them through the Onga Training Academy 2 Technologically advanced solutions for moving and treating water in the Home Garden Pool and Spa Innovative Stock and Crop water management solutions for Primary In...

Page 3: ...hat the performance of the valve meets the required application 6 Swimming pools or spa equipment wil not be warranted where the Langelier Saturation Index pH range is outside 7 2 to 7 6 and they have not been regularly treated with chlorine or bromine based sanitising systems or other recognised sanitising systems 4 Spare Parts Spare parts are usually stocked for a reasonable period of time follo...

Page 4: ...p equipment and installation The pump operator must be provided with this owner s manual This must be read before operation and followed during operation Do not run the pump without liquid Always ensure the pump is submerged before operation Do not allow the pump to continue running once the water supply is empty The pump cannot be used to move inflammable or dangerous liquids Isolate the pump ele...

Page 5: ... discharge piping and ensure that the suction is completely submerged Connect to power and pressure control device if required Do not submerge the pressure control device if installed Do not submerge the electrical connectors 2 Models and Technical Information Technical Data Model 7535 7556 11557 Inlet Screen Outlet 1 1 4 BSP Stages 5 8 8 Max Discharge Pressure m 35 56 57 Maximum immersion 20m Min...

Page 6: ...ied and the current absorption A decrease in pressure is a symptom of wear An increase in current absorption is a sign of abnormal mechanical friction in the pump and or motor If the submersible pump is not going to be used for long periods of time it should be emptied completely rinced with clean water and stored in a dry place Cleaning the filter If the water supply is not perfectly clean it may...

Page 7: ... 00 123 Ring Seal 1 00 126 Lubricant 1 00 127 O Ring Lower bearing flange 1 00 128 Flange Lower bearing holder 1 00 129 Stator Single phase wound 1 00 130 Motor body 1 00 133 Bushing Ceramic 1 00 135 Flange Upper bearing holder 1 00 139 Screw Inspection 2 00 144 Cable Power single phase w grommet 1 00 145 Base Filter 1 00 149 Flange Suction 1 00 159 O Ring Cover 4 00 166 Washer Seal compression 1 ...

Page 8: ...Water Flow Direction Wall or post Water Flow Direction Wall or post Water Flow Direction Wall or post Gap add spacer Controller not supplied Wa s Screws supplied Hose Fitting not supplied House Wall Use of Mounting Bracket Where possible please mount Constant Pressure Control Unit out of weather and with control panel in vertical Bracket Mounting Options The control device must be fitted verticall...

Page 9: ...avour has been made to publish the correct details in this data sheet No responsibility will be taken for errors omissions or changes in product specifications Pentair Water reserves the right to change specifications Pacific Head Office Australia Pentair Water Australia Pty Ltd Notting Hill Victoria Australia Tel 61 3 9574 4000 Fax 61 3 9562 7237 Email Sales pentairwater com au www pentairwater c...