background image

9

10

7. Troubleshooting 

Problem

The motor will not run, no 
water is pumped

Possible cause

1) No power supply
2)  Motor protection 

tripped

3) Defective capacitor
4) Pump blocked

Suggested Solution

1)  Check voltage at the 

supply, and check that 
the plug is connected 
securley

2)  Wait for internal

protection to reset.

3) Replace the capacitor.
4) Unblock the pump.

The motor runs, but no 
water is pumped.

1)  The pump is not 

submerged.

2)  The suction strainer is 

blocked.

3)  The check valve is 

blocked

1)  Check that the liquid 

level has not dropped 
below the minimum 
level.

2)  Clean the suction 

strainer.

3)  Clean or replace the 

valve

The pump stops after 
running for a short period 
of time (Thermal over-
load)

1)  The power supply is 

unsuitable.

2)  Solids are blocking the 

pump.

3) The liquid is too thick.

1)  Check the supply 

voltage.

2)  Have the pump 

disassembled and 
cleaned by an 
authorised dealer.

3)  See your dealer for an 

alternate pump.

6. Service & Maintenance

Under normal conditions DOMINATOR submersible pumps do not require any
maintenance. In order to avoid possible failures, it is advisable to periodically check
the pressure supplied and the current absorption. A decrease in pressure is a
symptom of wear. An increase in current absorption is a sign of abnormal
mechanical friction in the pump and/or motor.
If the submersible pump is not going to be used for long periods of time it should be
emptied completely, rinced with clean water and stored in a dry place.

Cleaning the fi lter

If the water supply is not perfectly clean, it may be nessary to clean the strainer with a
steel brush to scrape the dirt accumulated on the external surface. It is also
possible to clean the internal section of the strainer.
Loosen the screw that fi xes the strainer to the body of the electropump and remove it.
Scrape the dirt with a steel brush and rince it with clean water.

     

Always use origional service parts as supplied and recommended by Onga. 
Failure to do so may void warranty.

Do not operate the unit without the inlet strainer

Pumping water containing solids will reduce the life of the pump, 
and may affect warranty

If this is not suffi cent, have the hydraulic parts cleaned by an authorised service
center.

Pumping chemicals or agricultural products voids warranty.

Do not pump hydrocarbons with this pump.

If the pump is not going to be used for a long period, it should be completely 
emptied, rinsed with clean, fresh water, and stored in a dry place.

Summary of Contents for Dominator 11557

Page 1: ... of equipment you should contact the distributor manufacturer for the correct advice before proceeding with the installation or operation of this product For the Installation Operation and Service of Dominator Submersible Pump An earth leakage or residual current protection devide must be fitted to all instructions ...

Page 2: ... will 4 Our Team of Dealers The hand picked authorised Onga dealer network throughout Australia and worldwide are second to none We invest considerable time and resources training and supporting them through the Onga Training Academy 2 Technologically advanced solutions for moving and treating water in the Home Garden Pool and Spa Innovative Stock and Crop water management solutions for Primary In...

Page 3: ...hat the performance of the valve meets the required application 6 Swimming pools or spa equipment wil not be warranted where the Langelier Saturation Index pH range is outside 7 2 to 7 6 and they have not been regularly treated with chlorine or bromine based sanitising systems or other recognised sanitising systems 4 Spare Parts Spare parts are usually stocked for a reasonable period of time follo...

Page 4: ...p equipment and installation The pump operator must be provided with this owner s manual This must be read before operation and followed during operation Do not run the pump without liquid Always ensure the pump is submerged before operation Do not allow the pump to continue running once the water supply is empty The pump cannot be used to move inflammable or dangerous liquids Isolate the pump ele...

Page 5: ... discharge piping and ensure that the suction is completely submerged Connect to power and pressure control device if required Do not submerge the pressure control device if installed Do not submerge the electrical connectors 2 Models and Technical Information Technical Data Model 7535 7556 11557 Inlet Screen Outlet 1 1 4 BSP Stages 5 8 8 Max Discharge Pressure m 35 56 57 Maximum immersion 20m Min...

Page 6: ...ied and the current absorption A decrease in pressure is a symptom of wear An increase in current absorption is a sign of abnormal mechanical friction in the pump and or motor If the submersible pump is not going to be used for long periods of time it should be emptied completely rinced with clean water and stored in a dry place Cleaning the filter If the water supply is not perfectly clean it may...

Page 7: ... 00 123 Ring Seal 1 00 126 Lubricant 1 00 127 O Ring Lower bearing flange 1 00 128 Flange Lower bearing holder 1 00 129 Stator Single phase wound 1 00 130 Motor body 1 00 133 Bushing Ceramic 1 00 135 Flange Upper bearing holder 1 00 139 Screw Inspection 2 00 144 Cable Power single phase w grommet 1 00 145 Base Filter 1 00 149 Flange Suction 1 00 159 O Ring Cover 4 00 166 Washer Seal compression 1 ...

Page 8: ...Water Flow Direction Wall or post Water Flow Direction Wall or post Water Flow Direction Wall or post Gap add spacer Controller not supplied Wa s Screws supplied Hose Fitting not supplied House Wall Use of Mounting Bracket Where possible please mount Constant Pressure Control Unit out of weather and with control panel in vertical Bracket Mounting Options The control device must be fitted verticall...

Page 9: ...avour has been made to publish the correct details in this data sheet No responsibility will be taken for errors omissions or changes in product specifications Pentair Water reserves the right to change specifications Pacific Head Office Australia Pentair Water Australia Pty Ltd Notting Hill Victoria Australia Tel 61 3 9574 4000 Fax 61 3 9562 7237 Email Sales pentairwater com au www pentairwater c...

Reviews: