Please see complete manufacturer instructions for more information.
This supplement is designed to aid Oneida Air Systems customers with frequently asked questions.
You must have this product installed by a qualified and licensed electrician.
Improper installation is very dangerous and will void your warranty.
Follow all local & national electrical codes when installing this product.
This starter can be used in single or 3 phase applications. When used in 1 phase it
requires a jumper wire that connects T2 and L3. (See attached wiring diagram.) This
tricks the overload into thinking it has 3 phase power. This jumper must be installed by
a licensed electrician.
The jumper is not required if you are using 3 phase power.
Remove the blank plate and install the start
/ stop pushbutton into the starter cover.
You must mount the Overload Protector to the
contactor. The Overload comes in the small
white box. It mounts to the three terminals at
the bottom of the contactor.
See the complete
instructions for more information.
After mounting the overload, connect (2) brown
wires marked
95
&
96
to their respective
numbered terminals on the overload.
Important!
The gauge of the Jumper wire must match the gauge
of the wire bringing power to the motor thru the Starter.
Start / Stop
Pushbutton
XVI. Supplemental Instructions for Magnetic Motor Starters with
Oneida Air Systems Dust Collectors
5 - 7.5HP Direct Drive Owners Manual
O.A.S. 2008