4
V - Systems Owner’s Manual © O.A.S. 2010
III. System Specifications
Oneida V-1500™ 1.5hp /V -2000™ 2hp / V-3000™ 3hp / V-5000™ 5hp
Part #
Description
XXV010139H
XXV020139H
XXV030139H
XXV050139H
V-1500™ Collector
V-2000™ Collector
V-3000™ Collector
V-5000™ Collector
Performance:
V-2000™
6 inch pipe 1080 CFM @ 2.5” W/C SP
5 inch pipe 913 CFM @ 4.5” W/C SP
4 inch pipe 760 CFM @ 6.3” W/C SP
3 inch pipe 560 CFM @ 8.1” W/C SP
0 CFM @ 10.5” W/C SP
Performance:
V-1500™
6 inch pipe 949 CFM @ 1.8” W/C SP
5 inch pipe 739 CFM @ 3.5” W/C SP
4 inch pipe 572 CFM @ 5.3” W/C SP
3 inch pipe 467 CFM @ 6.1” W/C SP
0 CFM @ 7.9” W/C SP
(1.5hp)
83.7”
(2hp)
84.6”
(3hp)
84.6”
(5hp)
87.9”
Performance:
V-3000™
6 inch pipe 1105 CFM @ 3.3” W/C SP
5 inch pipe 955 CFM @ 5.3” W/C SP
4 inch pipe 790 CFM @ 7.2” W/C SP
3 inch pipe 587 CFM @ 9.0” W/C SP
0 CFM @ 11.75” W/C SP
Performance:
V-5000™
8 inch pipe 1498 CFM @ 1.65” W/C SP
7 inch pipe 1326 CFM @ 2.95” W/C SP
6 inch pipe 1210 CFM @ 4.05” W/C SP
5 inch pipe 988 CFM @ 6.9” W/C SP
0 CFM @ 13.6” W/C SP
Dimensions shown w/ 2” flex hose between drum and cone collars.
Allow 1 - 2” from ceiling for motor venting.
50”
25”
34”
30”
System
Performance
System
Dimensions
Options
Integral
Fan Blower
Filter Media
Included
Sound
Level
Dust Bin
U.S. Made Baldor or Leeson
1.5, 2, 3 or 5 Horsepower Single Phase
TEFC Motor, (2hp) 1.15 SF (3 / 5hp) 1.0 SF / Insulation
Class F for extra protection and motor life
Voltage: 115 (1.5) 230 (2 / 3 & 5hp)
Amperage: 8 (1.5) 11.5 (2hp) / 13 (3hp) / 19.5 (5hp)
(3) Tripod Aluminum Legs if stand is included.
Filter w/ Internal Silencer
FREE D.I.Y. Duct Design Guide
Flame Guard Arrestor - Pat. # 8,496,719
Pre-Wired Magnetic Starter -
Filter Grounding Wire
With Standard Silencer & Filter: 73 - 81 dBA @ 10’
Our Quietest System.
35 Gallon Fiber Drum - ODK350701 Standard
55 Gallon Fiber Drum - ODK550701 - Additional Charge
Fan Wheel - Backward Inclined / Non-Sparking, Non-
Ferrous as Required by NFPA Fire Code / Dynamic,
Two-Plane Balanced to ISO 6.3 Specifications. The Same
as Aircraft Turbine Rotors.
Industrial
Quality
Motor
*Oneida reserves the right to change or modify specs and system appearance without notice.
Actual system appearance may vary.
w/ On-Off Switch Preset for Add-On Remote
with Amperage Overload Protector (1 Phase)
See Accessories
page for pricing.
Remote Control - Radio Frequency
Bag Gripper
Shop Plan Design Service
Wall Mount
Approx. 949 CFM @ 1.8” S.P. (1.5hp)
Approx. 1080 CFM @ 2.5” S.P. (2hp)
Approx. 1105 CFM @ 3.3” S.P. (3hp)
Approx. 1498 CFM @ 1.65” S.P. (5hp)
13”x 36” 95 Sq. Ft. GE Certified (H-12) HEPA Media.
MERV 16+ rated.
See specs on website.
See Specifications Below
Line of Sight Not Required.
35 Gal.
61.75”
55 Gal.
73.75”
Ht. w/ 35 Gallon Drum:
(1.5hp) 83.7” - (2hp) 84.6” - (3hp) 84.6” - (5hp) 87.9”
Footprint w/ Ext. Cartridge: 30”x 50”
Inlet Diameter: 6”, 8” (5hp)
Powder Coated Paint Finish Over Steel
U.S. Pat. #
8,377,160