IV.  Dimensions

O.A.S. 2002

c

5HP High Pressure Owner’s Manual

5

22”

6 1/8”

28 1/2”

7 1/4”

36”

75 3/4”

111 7/8”

12”

62”

30 7/8”

10.031”

I.D.

7.64” I.D.

1.25”

Flange

For Minimum Mounting Heights

with 55 gal. drum

26 1/8” O.D. of

Mounting Ring

Bolt Holes

24 7/8”

18”

56”

Outlet Size

56”

7 3/4”

14 1/8”

18”

74 1/8”

17 3/16”

12 1/8”

5 1/16”

For Twin 55 Gal. Barrel Measurements

See Page 9.

Summary of Contents for 5HP High Pressure Dust Collector

Page 1: ...5HP High Pressure Dust Collector Oneida Air Systems Inc 1001 West Fayette St Syracuse N Y 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual...

Page 2: ...shipping cost Table of Contents Page Read the entire Owner s Manual before installing or operating system I II III IV V VI VII VIII IX X XI XII XIII 2 3 4 5 6 7 8 8 9 10 11 12 13 14 System Start Up I...

Page 3: ...s Caution The Dust Collector Fan Blower is heavy Handling and installation should always be performed by experienced and trained personnel who have experience with rotary equipment In addition to the...

Page 4: ...Pressure Owner s Manual 3 Pleated Cartridge Filters Do not remove fabric straps from cartridge Removable Dust Container Removable 55 Gal Metal Chip Dust Bin 5hp Integral Fan Blower Angle Iron Stand F...

Page 5: ...olyester BIA ZH1 487 test Rated C Captures 99 99 of test material over 20 microns Captures 99 9 of test material between 0 2 2 0 microns 11fpm External Cartridge Filter 55 Gal Steel Drums Large dust b...

Page 6: ...2 7 1 4 36 75 3 4 111 7 8 12 62 30 7 8 10 031 I D 7 64 I D 1 25 Flange For Minimum Mounting Heights with 55 gal drum 26 1 8 O D of Mounting Ring Bolt Holes 24 7 8 18 56 Outlet Size 56 7 3 4 14 1 8 18...

Page 7: ...ssure Owner s Manual V Angle Iron Stand Bolt together the stand using the cross bars and 3 8 x 1 bolts Note the cross bar on the cyclone stand goes in the back so that the dust bin can slide out 55 Ga...

Page 8: ...Integral Fan Blower Angle Iron Stand Outlet Inlet Elbow Square to Round Cone Cyclone Clamp Ring VI Assembly Instructions Cyclone Barrel Air Inlet Fan Blower 1 1 Orient the blower housing to match the...

Page 9: ...d ground per local and national codes Consult a licensed electrician with questions or if repairs are required Electrical Connections A All wiring fusing and grounding must comply with National Electr...

Page 10: ...om dust pan before or during the blow off process Let dust settle into dust pan Unclip and dump out dust Filter removal is not required You can also run your fingers around the filter pleats to knock...

Page 11: ...ie together Wiring should always be done by a licensed electrician Ground Connect house ground wire to green chassis screw in motor wire housing box Motor Wire Box Green Chassis Screw Top View Outlet...

Page 12: ...5hp high pressure dust collectors do not come wired or with an on off switch Because of the voltage and amperage requirements of the system an industrial switch must be used OAS offers Square D Full...

Page 13: ...rt or too small a branch line See branch line diameter chart in ductwork guide Be sure that your filter is clean See filter cleaning directions Filter Clogging Caused By Air leakage between cyclone an...

Page 14: ...below 420 microns in size 017 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an...

Page 15: ...stems shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Oneida Air Systems does no...

Reviews: