O.A.S. 2002
c
5HP High Pressure Owners Manual
4
III. General Specifications & Fan Performance Curves
Physical and Electrical Data for 5 hp High Pressure Unit.
5hp 2150 max cfm - 1270 cfm @ 10 Static
System Performance
Height w/ 55 Gal. Drum: 110 1/8
Footprint: 56 x 34
Fan Wheel diameter: 16 Backward Incline
designCyclone Inlet: 8
System Dimensions
TEFC 60 Hz Motor - Single Phase
Insulation Class: F4
Voltage: 230
Amperage: 19.5
Made in U.S.A.
Integral Fan Blower - 5hp
1 Pleated Cartridge - 130 sq. ft.
Spun-Bonded polyester BIA ZH1 / 487 test - Rated C
Captures 99.99% of test material over 20 microns
Captures 99.9% of test material between 0.2 - 2.0 microns @ 11fpm
External Cartridge Filter
55 Gal. Steel Drums
Large dust bins available
Dust Bin
Silencers available
Magnetic Motor Starters
Options
Static pressure and volume together determine a fans performance. Several factors, such as layout of
ductwork and diameter of openings, can affect a fans performance.
2500
2250
2000
1750
1500
1250
1000
750
500
250
0
0.00
2.00
4.00
6.00
8.00
10.00
12.00
14.00
Pressure vs. Volume @ Cyclone Inlet
5hp Fan Performance Curve
TEFC 60 Hz Motor - Three Phase
Insulation Class: F4
Voltage: 208 - 230/460
Amperage: 13.2 - 12 / 6
Made in U.S.A.