4.4.3 Timed Manual Override Control
The Manual control page allows overri-
ding the setpoint temporarily without
changing the current lighting curve. This
prevents accidentally leaving the lights on
when maintenance is finished.
To temporary override the current lighting setpoint, follow these steps:
1.
Select the
Activation time
of the setpoint (1 to 120 min) and the desired
Manual Intensity
of lighting (0 to 100%).
2.
Start the temporary override by checking the
Manual Control
checkbox.
The manual setpoint will be applied during the activation time; once this
time has elapsed, the manual lighting control is automatically deactivated.
Temporary Override
55 %
Current Intensity
Manual Control
30 min
Activation Duration
0 %
Manual Intensity
The temporary manual override mode can be ac-
tivated/deactivated in any program mode by si-
multaneously pressing on the up and down
arrows on the controller.
4.5
PRODUCTION
The AgriShift
®
ensures the monitoring and management of production
settings, as well as that of non-production times used for cleanup. This menu
allows starting or stopping production as well as changing the production
day.
To start production, follow these steps:
1. Enable the
In Production
option; the
Production page appears as follows:
2. Update the Production day (between 0
and 500). This day is used to determine which group(s) of lighting periods
is applicable (refer to section 4.4.2 Lighting - Curve for details).
Production
In Production
10
Day
b
4.5.1
Starting and Managing a Production
Summary of Contents for AgriShift LCL-0.2-120V
Page 2: ......
Page 35: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 33 ANNEX D WIRING DIAGRAM 3 1 1...
Page 36: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 34 NOTES...
Page 37: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 35 NOTES...
Page 38: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 36 NOTES...
Page 39: ......