AgriShift
®
Lighting Control Unit MASTER - Model LCL-0.2
16
SEC
TIO
N 4
4.4.1
Summary
The Summary page displays the general
lighting status:
- Current lighting setpoint and its nature:
h
non-production
: the setpoint comes
from the Production page (see section 4.5 for details).
h
production
: the setpoint comes from the Lighting - Curves page (see
section 4.4.2 for details).
h
override
: the setpoint comes from the Lighting - Temporary Manual
Override Control page (see section 4.4.5 for details).
- Current status and intensity of the lighting outputs:
h
AUTO
: the lighting output takes the setpoint defined above.
h
Switch
:
the output is set on manual operating mode. The intensity is
set by the Manual Intensity Adjustment Knob
.
h
Dim.
: (for variable output only): the lighting output takes the setpoint
of its external dimmer currently set to manual (0 to 100%). Set the dimmer
to Auto so that the lighting output takes the setpoint of the
AgriShift
®
system.
h
Manual
: The lighting output is under manual control (see section 4.6 for
details).
Setpoint (prod.)
Summary
10%
Actual Setpoint
Status
27%
27%
Dim.
27%
27%
Dim.
#
A
B
4.4
LIGHTING
Select the desired submenu and press
to view it.
Summary
Curve
Temporary Override
Lighting
To manage both outputs on separate
curves, the option "Independant"
must be selected in Advanced Para-
meters (see section
). The page will
then display as shown here.
Summary
Curve A
Curve B
Temporary Override
Lighting
Summary of Contents for AgriShift LCL-0.2-120V
Page 2: ......
Page 35: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 33 ANNEX D WIRING DIAGRAM 3 1 1...
Page 36: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 34 NOTES...
Page 37: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 35 NOTES...
Page 38: ...AgriShift Lighting Control Unit MASTER Model LCL 0 2 36 NOTES...
Page 39: ......