9051_Bedienungsanleitung_C1_Rev2_EN_UK – Stand 08.08.2018 TS / MB
24
10 Click codes of the controller
As soon as the motor controller is supplied with power, the controller uses the integrated relay to acoustically
inform the user about the system status and the reason for the most recent shut-down.
Click = Relay actuated, Clack = Relay dropping
Number
of click-
clacks
When
Status Information
1x
If the mains is on
Normal operation:
The system works without any
problem.
1x
Up key pressed
Reset
: Initialisation movement required
7x
During the movement, the connection to
a drive is lost.
Error
: Table cannot be moved any more
2x
Setting a container- or shelf-stop
Confirmation
of the limit position having been
successfully saved
(only with the simple hand switch without a display)
4x
Delete container- or shelf-stop.
Confirmation
of the limit position having been
successfully deleted.
(only with the simple hand switch without a display)
7x
Table moves at an angle
Error
: The drives do not have the same height,
initialisation movement required