3) Teach: Store a profile in the internal memory
Move the mode switch to the „FUN“ position, push key „1“ for „Meas“, and
again key „1“ for „TEACH“. Confirm the teach process with the key „1“ for „YES“.
The stored profile is used for setting the measurement region as well for the setting
of the position compensation in later steps. The tought profile is stored until the next
teaching, also if the sensor is powered down. After teaching 2 additional menu items
appear on the screen above:
•
3 SENS
•
4 CORECT
Remark:
In the menu „2 IMAGE“ you can find all settings regarding sensitivity and laser
intensity. For a first evaluation we can leave these settings unchanged. As a final
step the IMAGE settings can be optimized for tuning the measurement times to be
faster.
MENU
/VIEW
ESC
ADJ
FUN
RUN
STD EXP
SET
1
2
3
4
LD ON
ZERO
TRIG
T1
T2
T3
T4
MEAS
2 IMAGE
1 TEACH
„Meas“
„Teach“
T
u
to
ri
a
l