84
Section 4
APPENDIX
ZFV
User’s Manual
Section 4
Specifications and External Dimensions
Item
ZFV-SR10 (Narrow View)
ZFV-SR50 (Wide View)
Setting distance (L)
34 to 49 mm
38 to 194 mm
Detection range (H×V)
5 × 4.6 mm to 9 × 8.3 mm
10 × 9.2 mm to 50 × 46 mm
Relation between set-
ting distance and
detection range
Guide light
Provided (center, sensing area)
Built-in lens
Focus: f15.65
Focus: f13.47
Object lighting method
Pulse lighting
Object light source
Eight red LEDs
Sensing element
1/3-inch CCD, partial scan
Shutter
Electronic shutter, shutter time: 1/1,000 to 1/4,000
Power supply voltage
15 VDC (Supplied from Amplifier Unit.)
Current consumption
Approx. 200 mA
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
(destruction)
10 to 150 Hz, 0.35-mm single amplitude, 10 times each in X, Y, and Z directions for 8
min
Shock resistance
(destruction)
150 m/s
2
, three times each in six directions (up/down, left/right, forward/backward)
Ambient temperature
Operating: 0 to 40 °C, Storage: -25 to 65°C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Ambient atmosphere
Must be free of corrosive gas.
Connection method
Prewired, Standard cable length: 2 m
Degree of protection
IEC60529, IP65
Materials
Case: ABS, Mounting bracket: PBT
Weight
Approx. 200 g (including mounting bracket and cord)
Accessories
Mounting bracket (1), Ferrite core (1), Instruction sheet
49mm
34mm
5mm
9mm
Setting distance
Detection range (H)
(L)
10mm
194mm
38mm
50mm
Setting distance
Detection range (H)
(L)