The figure below shows the Basic Configuration of the ZFV Series.
■
Application Expanded Configuration
Up to five Amplifier Units can be gang-mounted.
When the Amplifier Unit is gang-mounted, a wider range of applications can be sup-
ported as simultaneous processing of multiple areas and measurement items can be
combined.
The image captured by the Sensor Head is transferred to the leftmost Amplifier Unit, so
connect to the rightmost Amplifier Unit.
Amplifier Unit
Detects workpieces as images.
• Narrow view type ZFV-SR10
• Wide view type ZFV-SR50
Sensor Head
Used for confirming images and menus, performing
measurement processing, and outputting the result
of processing.
• Single-function type ZFV-A10/-A15
• Standard type
ZFV-A20/-A25
Recommended OMRON power supply
(1) When 1 Amplifier Unit is connected
S82K-01524 (DC24V, 0.6A)
(2) When 2 or 3 Amplifier Units are connected
S82K-05024 (DC24V, 2.1A)
(3) When 4 or 5 Amplifier Units are connected
Prepare the required number of (1) and (2) power supplies above.
Power supply
DC24V (+10%, -15%)
Recommended power supply unit
Right
Wrong
Right
Wrong
• The maximum number of Amplifier Units that can be connected is five regardless of the number
of connected Sensor Heads.Six or more Amplifier Units cannot be connected.
• Provide power to all gang-mounted Amplifier Units.