![background image](http://html.mh-extra.com/html/omron/z550/z550_specifications_1633333003.webp)
B-59
Z550
Z550
Z550-SW70 Sensor
Sensor installation
Diffuse reflection only
Reference distance
(direction of height)
210 mm (for 60-mm measurement range mode)
Measurement
range
Direction of width
70 mm (at 200 mm-reference distance)
Direction of height
*1
*1.
For 60-mm measurement range mode
±30 mm max. (for 60-mm measurement range mode)
Light source
Visible semiconductor laser (wave length: 658 nm, 15 mW max, class 3B)
Beam dimensions
*2
*2.
Defined as 1/e² (13.5%) of the central light intensity. Leakage of light is also present in areas other than those defined. Thus, there are some influences in cases
where the reflection factor of the area surrounding the workpiece is higher than that of the workpiece itself.
120 µm x 75 mm typical at the 200 mm-reference distance
Resolution in the direction of width
*3
*3.
When an OMRON-standard workpiece (alumina ceramics) is placed at 200-mm distance, and edge position is measured. 60-mm measurement range mode is
used. The average of 16 measurements is taken. Note that the resolution performance may not be satisfied in the presence of strong magnetic fields.
0.1 mm
Resolution in the direction of height
*4
*4.
When an OMRON-standard workpiece (alumina ceramics) is placed 200-mm away and the average height of all lines is measured. The measuring range is 60
mm and the average of 16 measurements is taken. Resolution performance, however, may not be satisfied in the presence of strong magnetic fields.
10 µm
Linearity in the direction of height
*5
*5.
The error in relation to an ideal straight line when the average height of all lines on an OMRON-standard workpiece (alumina ceramics) is measured. The measuring
range is 60 mm. The degree of linearity may change depending on the workpiece.
±0.5% F.S.
LED indicator lamp
Lit when the laser is on
Temperature characteristic
*6
*6.
The value obtained at measurement with the space between the sensor and the workpiece fixed with an aluminum jig. The measurement range is 60 mm.
0.1% F.S./°C
Operation envi-
ronment robust-
ness
Degree of protection
IP66
Ambient operating
illumination
Illumination at light-receiving surface: 3,000 lx max., incandescent light
Ambient temperature 0 to +50°C at operation, -15 to +60°C at storage (no icing)
Ambient humidity
Operating and storage: 35% to 85% (no condensation)
Vibration (durability)
10 to 150 Hz (at a double amplitude of 0.35 mm) for 8 minutes each in the X, Y, and Z direc-
tions
Materials
Body: Aluminum die-cast
Cable sheathing: Heat-resistant PVC
Connector: Zinc alloy and brass
Cable length
0.5 m
Minimum bending radius
68 mm
Weight
Approx. 550g
Accessory
CLASS 3B Warning label (IEC60825-1: 1993 +A1: 1997) x 2
60-mm Range Mode
60 mm
60 mm
0 mm
0 mm
±
0.5% F.S. max.
Digital output
Distance