B-58
Displacement sensors / Width-measuring Sensors
Specifications
Z550-MC10/MC15 Controller
Model
Z550-MC10
Z550-MC15
I/O type
NPN
PNP
Power supply voltage
21.6 to 26.4 V DC
Current consumption
1 A max. (with 2 sensors connected)
Insulation resistance
Between the group of external DC terminals and the ground terminal: 20 M
Ω
max. (at
100 V DC ) (when the built-in surge absorber is removed)
Dielectric strength
Between the group of external DC terminals and the ground terminal: 1000 V AC at 50/60 Hz
(when the built-in surge absorber is removed)
Leakage current
10 mA max.
Noise resistance
1,500 Vp-p; Pulse width: 0.1 ms/1 ms; Rising edge: 1-ns pulse
Vibration resistance
10 to 150 Hz (at a double amplitude of 0.1 mm) for 8 minutes each in the X, Y, and Z directions
Shock resistance
200 m/s²; 3 times each in 6 directions
Ambient temperature
0 to +50 °C at operation, -15 to +60 °C at storage (no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (no condensation)
Ambient environment
No corrosive gases
Ground
D-type ground (ground resistance of 100 W or less) * conventional class 3 ground
Degree of protection
IEC60529 IP20 (in-panel)
Materials Console:
ABS
Weight
Approx. 0.7 kg
Number of connectable sensors
Up to two Z550-SW70 sensors can be connected.
Number of scenes
16
Averagin number
9 levels (1 to 256 times)
Sensor control
6 levels (varies depending on the sensor)
Area specification function
Available
Control of quantity of light
Multi-sensitivity adjustment (dynamic range or sampling interval takes precedence)
fixed sensitivity, automatic sensitivity adjustment
Measurement time
*1
*1.
The sampling interval varies depending on the measurement settings. Check the actual sampling interval on the image monitor.
100 ms (at fixed sensitivity)
120 ms (at automatic sensitivity)
100 ms to 250 ms (when sampling interval takes precedence)
100 ms to 620 ms (when dynamic range takes precedence)
Run Mode
Continuous measurement or trigger measurement
Image pre-processing
Noise removal
Measurement pre-processing
Interpolation processing, filter processing, Inclination compensation processing, Height and
position compensation processing
Detection method
Height position method, Reflectance method
Measurement item
Height, Step: 2 pts, Step: 3 pts, Edge position, Width, Edge center, Peak/Bottom, Cross-sec-
tional area, Inclination, Roughness, User-defined
Logging function
The measurement results of up to 3,000 measurements can be stored. (It is possible to select
the number ofmeasurements after which the measurement results will be stored.)
Output pre-processing
Forced zero, Offset/span adjustment
Profile data output
Up to 1024 height profiles can be output in one batch.
The output format may be either ASCII code or binary format (when sending via XMODEM)
Results output
Terminal block: Judgment result
Analog: Measurement result
RS-232C: Measurement result, judgment result, profile data
Screen display
Image monitor, Trend monitor, Digital monitor, Profile monitor
Tool function
Peripheral image display function, test measurement function
Terminal blocks
11 input points: TRIGGER, LD-OFF, RESET, DI0 to DI7
21 output points: DO0 to DO19 and GATE
RS-232C (Baud rate)
Up to 115 kbps (at XMODEM transmission, external trigger measurement) Normally 38.4 kbps
Monitor interface
1 channel (for pin jack or overscan monitor)
Analog output resolution
The full output scale can be divided into a maximum of 40,000 divisions.
Resolution
*2
: 0.25 mV (±5 V), 0.4 mA (4 to 20 mA)
*2.
When performing measurement taking the average of every 64 measurements with an OMRON K3AS linear sensor controller connected.