41
Precise Defect
Section 3-16
Comparing interval Y 1 to 32 [10]
Set the number of neighboring
elements compared with when
the degree of defect is calcu-
lated, For example, if the sam-
pling interval Y is set to 4 and
the comparing interval Y is set
to 2, comparison is with sepa-
rate elements of 4 x 2 = 8 pixels
along the Y axis.
Direction • X
(circumferential)
• Y (radial)
• Diagonal
Set the direction for detecting
defects.
The smaller the direction setting
count, the shorter the process-
ing time.
Setting item
Set value [Factory default]
Description