background image

RFID SYSTEM 

 

V680 Series 

User’s Manual

 

 

FL Remote ID 

V680-HAM42-FRT 

 

Antenna 

V680-HS63-SP 

 

ID Tag 

V680-D1KP66T-SP 

 

 

Summary of Contents for V680-D1KP66T-SP

Page 1: ...RFID SYSTEM V680 Series User s Manual FL Remote ID V680 HAM42 FRT Antenna V680 HS63 SP ID Tag V680 D1KP66T SP...

Page 2: ...observe the following items when using the RFID System Allow the RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems Read and under...

Page 3: ...RON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WA...

Page 4: ...t the uses listed may be suitable for the products z Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this manual z Nuclear...

Page 5: ...ish key specifications for your application on your request Please consult with your OMRON representative at any time to confirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dime...

Page 6: ...that may cause undesired operation FCC Part15 subpart B NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules Thes...

Page 7: ...ests for the appropriate requirements of the following relevant standards Radio EN 300 330 2V1 1 1 06 2001 EN 300 330 1V1 3 2 12 2002 EMC EN 301 489 3V1 4 1 08 2002 EN 301 489 1V1 5 1 11 2004 Safety E...

Page 8: ...ble 5 Do not allow water or pieces of wire to enter from openings in the case Doing so may cause fire or electric shock 6 Turn OFF the Controller power supply before mounting or removing an Antenna or...

Page 9: ...that can affect communications with the Tags If any of these devices are nearby communications with Tags may be affected or Tags may be destroyed If the product is to be used near such devices check...

Page 10: ...where the specified ambient storage humidity range is exceeded Locations where the product would be directly subjected to vibration or shock exceeding specifications Locations subject to contact with...

Page 11: ...nd functions 14 2 1 Part names 14 2 2 I O Specifications 19 2 2 1 Allocated I O 19 2 2 2 Signal functions 20 2 3 Memory map 21 2 4 ID tag communication functions 22 2 4 1 Operational mode 22 3 Communi...

Page 12: ...3 1 4 Bit clear 26 3 1 5 Data fill 27 3 1 6 Noise measurement 28 3 2 Timing chart 29 4 Appendix 30 4 1 Specifications 30 4 2 Dimensions 32...

Page 13: ...the electromagnetic induction type and is a product in accordance with International Standard ISO IEC18000 3 ISO IEC15693 of the RFID system 1 2 System Configuration PLC FL REMOTE Master unit HUB FL R...

Page 14: ...TE PIN No Name Description 1 TX_D1 Tranceive data output 2 TX_D1 Tranceive data output 3 RX_D2 Receive data input 4 5 6 RX_D2 Receive data input 7 8 Hood FG Ethernet connector Power supply connector A...

Page 15: ...nal 2 GND Analog ground Power supply connector connected to the 24VDC power supply Please use the bundled connector PIN No Name Description 1 V 24VDC terminal 2 GND Ground terminal 3 GR Functional ear...

Page 16: ...ote IO Green and Red blinking Connected to network Setting error Red Duplicate node address Red blinking Not connected to network Unlit Not connected to network TR ID transmission indicator Status Mea...

Page 17: ......

Page 18: ...Name Description 0 Trigger mode When the trigger signal is input from the plc FL REMOTE ID begins the communication with the ID tag and outputs the communication result to the plc 1 Auto mode When th...

Page 19: ...15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 CMD LEN CIO 0 OUTPUT TIME WR PROTECT VERIFY HISPD TRG INHIBIT 3 2 1 0 3 2 1 0 ADDR CIO 1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 OD1 OD0 CIO 2 7 6 5 4 3 2 1 0 7 6 5...

Page 20: ...ite verification 0 With write verification 1 Without write verification WR PROTECT Write protection function disable 0 Enabled 1 Disabled OUTPUT TIME Output time setting 0 100ms 1 500ms Slave unit to...

Page 21: ...memory area of up to 1 Kbytes Each address of the memory area specifies one byte A single byte of data can be written to one address Address Data 0000H to 0007H 1block 0008H to 0100H to 0200H to 0300...

Page 22: ...led in work or the palette is detected in the communication area of the antenna by the sensor or the switch and the control signal trigger signal is output from the plc to FL REMOTE ID This FL REMOTE...

Page 23: ...ion NORM 1 0 or 1 Normal completion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication ID 32 Read data Example Data read of 3 bytes from 120H addresses Outp...

Page 24: ...1 Normal completion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication Example Data write of 3 bytes from 321H addresses Output bits 15 14 13 12 11 10 9 8...

Page 25: ...ompletion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication ID 32 Data after bit set Example Bit set of 1 byte from FFH addresses Output bits 15 14 13 12 1...

Page 26: ...l completion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication ID 32 Data after bit clear Example Bit clear of 4 bytes from FH addresses Output bits 15 14...

Page 27: ...r 1 Normal completion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication Example Data fill of 16 bytes from 6H addresses Output bits 15 14 13 12 11 10 9 8 7...

Page 28: ...Abnormal completion ID 32 Measurement result ID0 Average value 00 63H ID1 Maximum value 00 63H ID2 Minimum value 00 63H ID3 00H fixed Example Output bits 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 CIO 0 0...

Page 29: ...E ID makes NORM 1 on Please make TRG 0 off after the NORM signal turn to 1 on BUSY and NORM when FL REMOTE ID confirms TRG is turned off When ID tag is outside the communication area F The plc makes T...

Page 30: ...al durability 150m s2 3times each in 6 directions Degree of protection Panel mounting conforms to IP20 Material PC ABS resin Weight Approx 150g Mounting method DIN Track or M4 screws Antenna V680 HS63...

Page 31: ...rage 40 to 110 no freezing no dew condensation Ambient humidity Operating 35 to 95 RH storage 35 to 95 RH no freezing no dew condensation Vibration resistance Mechanical durability 10 to 2 000Hz doubl...

Page 32: ...4 2 Dimensions FL REMOTE ID V680 HAM42 FRT...

Page 33: ...Antenna V680 HS63 SP ID tag V680 D1KP66T SP...

Reviews: