![background image](http://html1.mh-extra.com/html/omron/v680-d1kp66t-sp/v680-d1kp66t-sp_user-manual_741402020.webp)
2.2.2.
Signal functions
<Master unit to Slave unit>
Signal
Name
Description
OD0-0 to 7
OD1-0 to 7
OD2-0 to 7
OD3-0 to 7
Data output
Output write data to the ID tag
ADDR0 to 15
Address
Specify start address for reading or writing.
Setting range:
0000H to FFFFH
LEN0 to 4
Data length
READ, WRITE;
specify the data length by the number of bytes
Setting range:
1
H to 4H
DATA FILLI;
specify the data length by the number of blocks
Setting range:
0
H to FH
CMD0 to 3
Command
Specify the executing command
0000B Data
read
0001B Data
write
0010B Bit
set
0011B Bit
clear
0100B Data
fill
1111B Noise
measurement
Trigger mode
When this signal is “1", FL REMOTE ID begins the communication
with the ID tag
TRG/~INHIBIT Trigger
input/~Inhibit
Input
Auto mode
When this signal is “0", FL REMOTE ID stops the communication
with the ID tag
HISPD High-speed
Data
Transmission setting
“0” Normal
mode
“1” High
speed
mode
VERIFY Write
verification
“0”
With write verification
“1”
Without write verification
WR PROTECT
Write protection
function disable
“0” Enabled
“1” Disabled
OUTPUT TIME
Output time setting
“0”
100ms
“1” 500ms
<Slave unit to Master unit>
Signal
Name
Description
ID0-0 to 7
ID1-0 to 7
ID2-0 to 7
ID3-0 to 7
Data input
Input read data from the ID tag
RUN
RUN
Turns “1” when FL REMOTE ID is operating normally and the communications are possible
with the plc
BUSY
BUSY
Output when a tag communications continues
NORM
Normal output
Output when communications with the ID tag are completed normally
ERR0
Error 0 output
Output when communications with the ID tag are not completed normally
ERR1
Error 1 output
Output when the command is illegal
ERR2
Error 2 output
Output in the mode error
ERR3
Error 3 output
Output when FL
REMOTE ID is inoperative
ERR_SUB0
Error sub 0
No tag error
ERR_SUB1
Error sub 1
ID tag communication error
ERR_SUB2
Error sub 2
ID tag address error
ERR_SUB3
Error sub 3
Write protect error
ERR_SUB4
Error sub 4
Verification error
ERR_SUB5
Error sub 5
System error
ERR_SUB6
Error sub 6
System error
Summary of Contents for V680-D1KP66T-SP