3.2.
Timing chart
ID tag
TRG
RUN
BUSY
NORM
ERR1
ERR_SUB
ID
A B
C D E
F G
ID tag in communication area
H
I J
<When ID tag is in the communication area>
A:The plc makes TRG “1" (on) and directs the execution to FL REMOTE ID.
B:FL REMOTE ID fixes CMD (command), LEN (data length), and ADDR (start address), the communication
with the ID tag begins, and BUSY is “1" (on).
C:When the communication with the ID tag completed normally, FL REMOTE ID makes NORM "1" (on).
D:Please make TRG “0" (off) after the NORM signal turn to 1" (on).
E:BUSY and NORM when FL REMOTE ID confirms TRG is turned off.
<When ID tag is outside the communication area>
F:The plc makes TRG “1" (on) and directs the execution to FL REMOTE ID.
G:FL REMOTE ID fixes CMD (command), LEN (data length), and ADDR (start address), the communication
with the ID tag begins, and BUSY is “1" (on).
H:When the communication with the ID tag did not complete normally, FL REMOTE ID makes ERR1 and
ERR_SUB0.
I:Please make TRG “0" (off) after the ERR1 signal turn to 1" (on).
J:ERR1 and ERR_SUB0 when FL REMOTE ID confirms TRG is turned off.