Troubleshooting
71
■
From Trial Operation to Communications
Errors are indicated by the status of the indicators after transmission of the write command, and by the
response code of the response.
• If the ID Tag Was Processed Normally:
If there is no response to the write command, refer to the
From Installation to Trial Operation
,
Operation Check Flowchart
.
Refer to page 69.
Indicators
RUN
COMM
NORM
ERROR
Response Code for the Response
Type
Response
code
Function
Normal
00
The ID Tag was processed normally.
Error occurrence
Is the response
code 1
?
No
Yes
Check the command format.
If the response code is 1
Refer to page 72.
Yes
Communications with the ID Tag has failed.
If the response code is 7
Refer to page 72.
Write command sent
RUN indicator
OFF?
No
Yes
An error has occurred at the Amplifier Unit.
Amplifier Unit error
Refer to page 72.
Is the response
code 7
?
Communications OK
No
(Lights once)
(Lights once)