38
SECTION 4
Command/Response Format
CIDRW System
User’s Manual
SECTION 4
Reading from/Writing to ID Tags
■
SAME WRITE
This command writes the same data to multiple pages of an ID Tag. Any page(s) can be specified.
ID Tag Memory Maps
Refer to page 111.
The response code (when normal: 00) is returned.
Example: Clearing All Data on Pages 1 and 17 of the Amplifier Unit to 0
Parameter Description
Parameter
Description
Page designation
Pages are specified by setting the bits corresponding to pages that are to be read to 1 and setting
the other bits to 0, then converting the result to a hexadecimal character string.
Write data
Specify the write data.
Response
code
CR
0
0
0Dh
Response
code
CR
0
0
0Dh
Command
Command code
Page designation (8 characters)
Write data
CR
Data 1
⋅ ⋅ ⋅
Data 8
0
3
0
0
0DH
Bit
7
-
0
7
-
3
2
1
0
7
6
-
1
0
7
6
-
2
1
0
Page
Sys
-
Sys Sys
-
Sys
17
16
15
14
13
-
8
7
6
5
-
1
Sys Sys
Designation
0*
0*
0*
0*
0*
0/1
0/1
0/1
0/1
0/1
•••
0/1
0/1
0/1
0/1
•••
0/1
0*
0*
Value
00
00 to 07
00 to FF
00 to FC
* Always specify 0. If you specify 1 an error (Response code: 14) will occur.
Response
Command
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
Binary
notation
Command
code
Page designation
Write data
CR
0 3 0 0 0 0 0 7 F F F C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Dh
Response