SECTION 1
Product Outline
Component Names and Functions
V640-HAM11-ETN-V2 and V640-HAM11-L-ETN-V2 Amplifier Units
No.
Name
Function
1
Dedicated power supply con-
nector
Connect to the 24 VDC power supply.
2
Ethernet port
Connect to the host device through a LAN cable.
3
RUN indicator (green)
Turns ON when the Amplifier Unit is in normal operation.
4
COMM indicator (yellow)
Turns ON during communications with the host device or during communications with an
ID Tag.
5
NORM indicator (green)
Turns ON when the communications finish with no error.
6
ERROR indicator (red)
Turns ON when an error occurs during communications with the host device, or during
communications with an ID Tag.
7
CIDRW Head connection port A CIDRW Head is connected here.
The V640-HS61 CIDRW Head is used with the V640-HAM11-ETN-V2. The V640-HS62
CIDRW Head is used with the V640-HAM11-L-ETN-V2.
8
Setting DIP switches
Set the IP address and enable/disable the Test Mode with this DIP switch.
LINK(green)
ACT(yellow)
LINK---lights while linking normally.
ACT---lights when detects a carrier.