Available Address List 

 

(1) SYSMAC C Series(Common) 

 

Dev 

Input 

50,120(F),500(F) 

2000H, 

200H(S), 

1000H(F) 

Data Link 

LR 

0~31 

0~63 

Latch Relay 

HR 

0~31 

0~99 

Timer 

TIM 

0~127 

0~511 

Counter 

CNT 

0~127 

0~511 

Data Memory 

DM 

Refer following List. 

Aux. Memory 

AR 

None 

0~27 

I/O Relay 

CH 

0~63 

0~255 (0~511:200HS) 

 

(DM Area) 

C50,120,500 

0~511 

C200H   

0~1999 

C200HS 

0~9999 

1000H 

0~4096 

2000H 

0~6655 

120F 

0~511 

500F 

0~4095 

1000HF 

0~4095 

* Bit ON/OFF control is available in LR,HR,AR,CH. 

 

(2) SYSMAC CV Series 

Dev 

Input 

CV 

Data Link Relay 

 

1000~1199 

Special Hold Relay 

000~511 

Timer(Current Value) 

0~1023 

Counter(Current Value) 

0~1023 

Data Memory 

0~9999 

Internal    Aux. Relay 

 

1900~2299 

I/O Relay 

 

000~199 

Summary of Contents for SYSMAC Series

Page 1: ...Communication Interface Manual Published by M2I Corporation M2I Corporation...

Page 2: ...C200HS C200H LK202 V1 Refer to cable diagram RS 422 ALL TOP C200H LK201 V1 Refer to cable diagram RS 232C C500 C1000H C2000H C500 C500 LK201 V1 C500 LK203 Refer to cable diagram RS 232C 422 C50 C120 C...

Page 3: ...am for SYSMAC C PLCs except C200 CS1 CJ1 CPM1A 2A 2C Comm Link Module 25Pin TOP 9 15Pin 2 RS 232C SYSMAC C200 TOP for 9 15 Pin Connector This is connection diagram for SYSMAC C C200 Comm Link Module 9...

Page 4: ...Terminal Block 15pin 4 RS 422 SYSMAC C200 TOP for 5Pin Terminal Block or 15Pin Connector This is connection diagram for SYSMAC C PLC C200 Comm Link Module 9Pin TOP 5Pin Terminal Block 15Pin 1 11 RDA 2...

Page 5: ...2 1200 3 2400 4 4800 5 9600 6 19200 3 Command Level Setting Set by SW4 Recommend 2 Switch Command Level Parity Etc 0 Level 1 available even ASCII 7bit 2 Stop bit 1 Level 1 2 available 2 Level 1 2 3 av...

Page 6: ...etting 4 DIP Switch Setting ON 1 2 3 4 Terminator Exist None 1 1 1 N CTS Toggle External 0V Always ON Mode C200H LK201 V1 C200H LK202 V1 SW No ON OFF OFF Fixed OFF Fixed 1 2 3 4 1 N 1 1 5V Supply None...

Page 7: ...N 4 OFF OFF OFF ON ON 5 OFF OFF OFF ON ON 6 Not Used 7 Not Used 8 Power On PLC Mode Run Stop SW2 1 4 Baud Rate 300 600 1200 2400 4800 9600 1920 0 1 Baud Rate Setting OFF ON OFF ON OFF ON OFF 2 ON OFF...

Page 8: ...Internal External Terminator None Exist CTS 0V External 5V Supply ON OFF Switch Setting Item Set Switch Status ON OFF SW1 1 5 Assign Station Num 0 1 2 30 31 1 Station Num Setting OFF ON OFF OFF ON 2...

Page 9: ...e Setting OFF ON OFF ON OFF ON OFF 2 ON OFF OFF ON ON OFF OFF 3 OFF OFF OFF ON ON ON ON 4 ON ON ON OFF OFF OFF OFF 5 Select System System 0 System 1 6 Mode 1 1 1 N 7 8 Command Level 1 1 1 2 1 2 3 7 Co...

Page 10: ...FF OFF OFF ON ON 4 OFF OFF OFF ON ON 5 OFF OFF OFF ON ON 6 Not Used 7 Not Used 8 Power On PLC Mode Run Stop SW2 1 4 Assign Baud Rate 300 600 1200 2400 4800 9600 1920 0 1 Baud Rate Setting OFF ON OFF O...

Page 11: ...LK202 V1 Switch Setting Item Set Switch Status 1 2 Terminator Exist None 1 ON ON 2 OFF OFF 3 ON OFF 4 OFF OFF 5 ON OFF 6 OFF OFF 7 Not Used 8 Not Used Recommended Settings are Internal Sync Terminator...

Page 12: ...f PLC must be MONITOR Otherwise Write to PLC is not available This is how to use communication unit for RS 422 Following dip switch is located inner of C200HW COM06 ON SW1 SW2 1 2 4 RS422 RS485 in cas...

Page 13: ...e as follows Serial Baud Rate Same as controller s setting Serial Data Bit Same as controller s setting Serial Stop Bit Same as controller s setting Serial Parity Bit Same as controller s setting Seri...

Page 14: ...diagram RS 232C ALL TOP CPM1 CIF11 Refer to cable diagram RS 422 CPM2C CPM2C CIF01 Refer to cable Diagram RS 232C CPM2C CIF11 Refer to cable Diagram RS 232C RS 422 Cable Diagram 1 RS 232C CPM1A 2A 2C...

Page 15: ...TOP CPM1A 2A 2C 9Pin TOP 5Pin Terminal 15Pin TOP Setup 1 TOP Designer Setup Select OMRON SYSMAC C of OMRON Series in PLC Type 1 11 RDA 2 12 RDB 3 13 SDA 4 14 SDB 5 15 SG 1 RDB RD 2 3 SG 4 5 SDB SD 6 R...

Page 16: ...ntroller s setting Serial Data Bit Same as controller s setting Serial Stop Bit Same as controller s setting Serial Parity Bit Same as controller s setting Serial Signal Level Same as controller s set...

Page 17: ...emory AR None 0 27 I O Relay CH 0 63 0 255 0 511 200HS DM Area C50 120 500 0 511 C200H 0 1999 C200HS 0 9999 1000H 0 4096 2000H 0 6655 120F 0 511 500F 0 4095 1000HF 0 4095 Bit ON OFF control is availab...

Page 18: ...Data Register DR 0 15 Timer CV T 0 4095 Counter CV C 0 4095 Data Memory D 00000 32767 Internal AUX Relay W 0 511 Channel I O CIO 0 6143 Hold Relay H 0 511 Special Auxiliary Relay A 0 959 Exp Data Memo...