EtherCAT Connection Procedure
25
7.4. EtherCAT Communication Status Check
Confirm that PDO communications via EtherCAT is performed normally.
7.4.1. Checking the Connection Status
Check the EtherCAT connection status.
1
Check with the LED indicators
on Controller that PDO
communications via EtherCAT is
performed normally.
The LED indicators in normal
status are as follows:
NET RUN: Green lit
NET ERR: Not lit
LINK/ACT: Yellow flashing
*The NJ-series Controllers also
have the same LED indicator
status.
2
Check the LED indicators on Dry
Vacuum Pump.
The LED indicators in normal
status are as follows:
RUN:
Green lit
ERROR: Not lit
LINK/ACT: Green blinking
Built-in EtherCAT (Port 3)
Status Indicators