background image

Displays relevant data items, such as frequency reference,

output frequency and parameter set values.

Sets the frequency reference within a range between 0Hz

and the maximum frequency.

The frequency reference can be monitored or set while this

indicator is lit.

The output frequency of the Inverter can be monitored or

set while this indicator is lit.

The output current of the inverter can be monitored while

this indicator is lit.

The values set in U01 through U18 are monitored while

this indicator is lit.

The direction of rotation can be selected while this indicator

is lit when operating the Inverter with the RUN Key.

The operation of the Inverter through the Digital Operator

or according to the set parameteres is selectable while this

indicator is lit.

Note:

The status of this indicator can be only monitored 

while the Inverter is in operation. Any RUN 

command input is ignored while this indicator is lit.

The parameter in n01 through to n179 can be set or moni-

tored while this indicator is lit.

Note:

While the Inverter is in operation, the parameters 

can be only monitored and only some parameters 

can be changed. Any RUN command input is 

ignored while this indicator is lit.

Switches the setting and monitor item indicators in

sequence.

Parameter being set will be cancelled if this key is pressed

before entering the setting.

Increases multi-function monitor numbers, parameter num-

bers and parameter set values.

Decreases multi-function monitor numbers, parameter

numbers and parameter set values.

Enters multi-function monitor numbers, parameter numbers

and internal data values after they are set or changed.

Starts the Inverter running when the 3G3MV is in operation

with the Digital Operator.

Stops the Inverter unless parameter n007 is not set to 

disable the STOP Key.

Data display 

FREQ adjuster

FREF indicator

FOUT indicator

IOUT indicator

MNTR indicator

F/R indicator

LO/RE indicator

PRGM indicator

Mode Key

Increment Key

Decrement Key

Enter Key

RUN Key

STOP/RESET Key

Appearance

Name

Function

DIGITAL OPERATOR
PJVOP 140

MIN

MAX

FREQUENCY

FREF

FOUT

IOUT

MNTR

F/R

LO/RE

PRGM

RUN

STOP

RESET

Data display

Keys

Indicators
(Setting/Monitor
item indicators)

FREQ adjuster

Summary of Contents for SYSDRIVE 3G3MV SERIES

Page 1: ...eu omron com 1 Apsley Way Staples Corner London NW2 7HF Fax number 020 8233 1468 Factory automation technical support 24hr technical helpsheet datasheet faxback service 020 8450 4646 General telephone...

Page 2: ...input common R R S S AC See Note 2 Multi function input 1 Multi function input 2 Multi function input 3 Multi function input 4 Multi function input 5 Multi function input 6 Multi function input 7 Seq...

Page 3: ...utput common Multi function analog output Output Freq Multi function analog output common Photocoupler 8mA at 24 V DC See note 2 3 20mA at 12 V DC 0 to 10 V DC 20W Response frequency 0 to 33 kHz 30 to...

Page 4: ...Recommendations Noise Filter Specifications Y W X d H L D 8 5 Four 5 dia H1 H W1 W H 128 128 128 128 128 128 128 128 128 128 128 128 128 128 260 260 H1 118 118 118 118 118 118 118 118 118 118 118 118...

Page 5: ...dicator is lit Note While the Inverter is in operation the parameters can be only monitored and only some parameters can be changed Any RUN command input is ignored while this indicator is lit Switche...

Page 6: ...ogue output Carrier Frequency DC Injection Braking Current DC Injection Braking at Stop Time DC Injection Braking at Start Time Stall pevention during deceleration 0 Stall prevention enabled 1 Braking...

Page 7: ...ence 3 9 Multi step speed reference 4 10 Inching command 12 External base block NO 13 External base block NC 17 Local Remote selection Multi function Outputs Value Function 0 Fault output 1 During RUN...

Page 8: ...igital input has been set to 12 or 13 Forward and reverse run signal have been applied simultaneously The values in n050 through n056 for multi function inputs 1 through 7 have been duplicated check a...

Reviews: