Input/Output Circuit and Applications
Connecting a F3SJ-B to a G9SP
•Emergency stop switch can be connected
•Door switch, two hand control, single beam sensor, or relay unit can be used in combination with
G9SP.
S3
S4
+24 V (Brown)
Not used (White)
Reset input (Yellow)
External device
monitoring input (Red)
Auxiliary output (Yellow)
Shield
Shield
Not used (Red)
+24 VDC
0 V
Power
supply
V1
Si0
Si1
G1
GND
S1
T0
11
12
22
21
T1
Si2
Si3
Si4
Si5
Si6
Si7
T2
T3
So0
So1
V2
G2
G2
G2
S2
M
KM1
KM2
GND
KM1
KM1
KM2
KM2
S1
S2
S3
S4
KM1, KM2
M
: Emergency stop switch
(force-opening contact) (A165E, A22E)
: Reset switch
: External test switch (connect to 24 V if a switch is not required)
: Lockout reset switch (connect to 24 V if a switch is not required)
: Safety relay with force-guided contact (G7SA)
or magnetic contactor
: 3-phase motor
Receiver
Emitter
Communication line (+) (Gray)
Communication line (-) (Pink)
0 V (Blue)
T
est input (Black)
+24 V (Brown)
Safety output 1 (Black)
Safety output 2 (White)
0 V (Blue)
F39-JD
A-L
F39-JD
A-D
+24 VDC
0 V
Power
supply
+24 VDC
0 V
Power
supply
KM1,KM2 N.C. contact
Unblocked
Blocked
External test switch
(S3)
Reset switch
(S2)
Safety output
KM1,KM2 N.O. contact
Emergency stop switch
(S1)
- F3SJ-B settings
- Does not use external device
monitoring function
- G9SP settings
- Manual reset mode
- Using feedback loop
Feedback loop
Summary of Contents for Sti F3SJ-B P25-01TS Series
Page 1: ...F3SJ B P25 01TS Series Safety Light Curtain User s Manual Cat No SCHG 734C ...
Page 12: ...x Introduction F3SJ B User s Manual ...
Page 82: ...68 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation ...
Page 92: ...78 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications ...
Page 98: ...84 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists ...