Description of Functions
External Test Function
This function stops the emission using an external signal. It can be used to verify that a safety system
should properly stop (safety output turns OFF) when F3SJ-B is interrupted.
To stop the emission, open the test input line or apply voltage of 0 V to 1/2 Vs to the emitter's test input
line.
Test input
Safety output
ON
OFF
ON
OFF
60 ms max.
140 ms max.