57
F3SJ-B
User’s Manual
Ch
apt
e
r
3
Moun
ting
Wiring/Installation
E
When using One-touch Bracket
<Precautions on mounting the sensor using One-touch Brackets>
When using two One-touch Brackets to mount a sensor, the combination of One-touch M6 Bracket (or
One-touch M8 Bracket) and Intermediate Bracket at the both ends of the sensor must be positioned
opposite each other. When using three or more Brackets, One-touch M6 Brackets (or One-touch M8
Brackets) and Intermediate Brackets at other positions than the both ends must be in the same
orientation.
Mount One-touch M6 Brackets (or One-touch M8 Brackets) according to the mounting positions of the
emitter and receiver. The positions of Intermediate Brackets mounted to the emitter and receiver must
be aligned with each other.
(Good example 1) (Good example 2)
(Bad example 1) (Bad example 2)
Emitter
Receiver
Emitter
Receiver
One-touch M6 Brackets (One-touch M8 Brackets)
Aluminum profile
<Position of the bracket to be mounted to the sensor>
<Side view of the aluminum profile to be mounted>