11
F3SJ-B-01T
Quick Installation Manual
□
The sensor can detect a test rod wherever it is in the detection zone. In other words, when a test rod is
inserted into the detection zone, the stable-state indicators (STB) turn off and the ON/OFF output-state
indicators turn red.
□
When the external test function is used:
The ON/OFF-state indicator turns ON in red when the test input line is set to open or short-circuited to 1/
2 Vs to Vs or open.
-Checking that Hazardous Parts Stop While the Machine Operates
□
The hazardous parts stop immediately when a test rod is inserted into the detection zone at three posi-
tions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter and
receiver". (Use the appropriate test rod.)
□
The hazardous parts remain stopped as long as the test rod is in the detection zone.
□
The hazardous parts stop when the power of the F3SJ-B-01T is turned OFF.
□
The actual response time of the whole machine is equal to or less than the calculated value.
Maintenance Checklists
To ensure safety, keep a record of the inspection results. When the user is a different person from those who
installed or designed the system, he/she must be properly trained for maintenance.
■
Checklists
-Inspection at Startup and When Changing Operators
□
There is no approach route other than through the detection zone of the F3SJ-B-01T.
□
Part of the operator's body always remains in the detection zone of the F3SJ-B-01T when working around
the machine's hazardous part.
□
The actual safety distance is equal to or greater than the calculated value.
□
There must be no dirt on or damage to the optical surface and spatter protection cover (F39-HB
□□□□
,
sold separately) of the F3SJ-B-01T.
□
The ON/OFF-state indicator turns ON in red when the test input line is set to open or short-circuited to 1/
2 Vs to Vs or open.
□
The test rod is not deformed.
□
When the power of the F3SJ-B-01T is turned ON while nothing is in the detection zone, it must operate as
follows:
The power indicator and ON/OFF-state indicators turn green within 2 seconds after the F3SJ-B-01T is
turned ON.
□
Nothing should exist in the detection zone and stable-state indicators must turn ON at power on.
□
The test rod is detected when it is moved around in the detection zone as shown in the diagram of Pre-
Operation Checklists.
In other words, when a test rod is inserted into the detection zone, the stable-state indicators (STB) turn
off and the ON/OFF-state indicators turn red.
□
Neither connector nor bracket must be loose.
-Checking that Hazardous Parts Stop While the Machine Operates
□
The hazardous parts are movable when nothing is in the detection zone.
□
The hazardous parts stop immediately when a test rod is inserted into the detection zone at three posi-
tions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter and
receiver". (Use the appropriate test rod.)
□
The hazardous parts remain stopped as long as the test rod is in the detection zone.