No.19S019-01
1
23
STC-APB503PCL / STC-APC503PCL
Product Specifications and Use’s Guide
9.4.2
Description of the camera control commands (Bank number: 00H)
The underline settings are the factory default settings.
Command No.
Command Description
10H:
MOD1 [7..0]
[Camera function mode 1] Default data: MOD1 [7..0] = 01H
Sets the camera function mode.
D7
D6
D5
D4
D3
D2
D1
D0
D7
Trigger Mode Selection
0: Auto
1: Manual
D6
Trigger Polarity
0: Positive
1: Negative
D5
Trigger Mode
0: Edge Preset
1: Pulse Width
D4
Binning Mode *1
0: OFF
1: ON
D3 to D1
No Function
Always set as “000”
D0
CMOS Shutter Mode
0: Rolling (ERS)
1: Global Reset (GRR)
*1 Only available for monochrome model (Please sets 0 for color model)
11H:
MOD2 [7..0]
[Camera function mode 2] Default data: MOD2 [7..0] = 00H
Sets the camera function mode.
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D4
No Function
Always set as “0000”
D3
Operation Mode
0: Trigger
1: Free-run / Continuous
D2 to D0
No Function
Always set as “000”
* Note: While the camera is in trigger mode, the image will not output without the trigger signal input.
12H:
MOD3 [7..0]
[Camera function mode 3] Default data: MOD3 [7..0] = 40H
Sets the camera function mode.
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D6
Output Format
00: 10bits
01: 8bits
10 to 11: No Function
D5
Trigger Input
0: CC1 on Camera Link
1: 2pin on power-I/O
D4 to D0
No Function
Always set as “00000”
14H:
UART [7..0]
[Communication mode] Default data: UART [7..0] = 01H
Sets the communication mode.
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D2
No Function
Sets always as "000000"
D1 to D0
Communication Mode
00: 38,400 bps
01: 9,600 bps
10: 57,600 bps
11: 115,200 bps