Safety 

Technology 

& Innovation 

SR104P 

The arrangement of the two-hand buttons must be designed in accordance with the standard EN 574 such that accidental 

actuation or simple bypassing of the safety function is excluded. 
The  SR104P  unit  is  provided  for  the  connection  of  2-hand  push-buttons,  with  one  normally  open  or  one  normally  colsed     

contact. 
 
Figur 1 shows the wiring of the SR104P with a 2-hand push-buttons: 

Applications 

Fig. 1: 

Wiring of the SR104P with a 2-hand push-

buttons 

Fig. 2: Feedback loop  

Contactors connected to the SR104P or the basic devices are 

monitored via the feedback loop of the basic device. K

A

 and 

K

B

 are the positively driven contacts of the connected contac-

tor or expansion module. 

Feedback loop 

Note:   The items listed under “Electrical connection” must be observed during commissioning. 

Commissioning 

Procedure 

1. Wiring SR104P: 
Wire  the  SR104P  with  the  OMRON  STI  basic  device  ac-

cording to your application (see Fig. 1). 
 
 2. Wiring feedback loop: 
Wire the feedback loop as shown in Fig. 2. 

 

3. Wiring power supply:  
Connect the power supply to terminals A1 and A2. 
 
Warning:  Wiring only in de-energized state. 
 

4. Starting the device: 

 

Switch the operating voltage on. 
 
5. Switch to working condition: 
Press the two buttons T1 and T2 simultaneously, or within 

0.5 seconds. 
The positive-guided relay switches. 
 
6. Switch into hibernation: 
Release the two buttons T1 and T2. 
The positive-guided relay swiches off. 

Jumper X1-X2:  
See description  

X1 

X2 

Installation 

Avoiding unintentional actuation or bypassing of the safety device

 

The arrangement of the two-hand buttons must be designed in accordance with the standard EN 574 such that accidental 

actuation or simple bypassing of the safety function is excluded. 
The operation of both buttons using one hand must be prevented by an adequate distance (at least 260mm) or by a separa-

ting wall. Actuation using forearm, elbow, knee, hip or other parts of the body can be effectively prevented by a further inc-

rease in the distance between the two buttons, adequate distance from the floor and/or covers and/or separating walls. 

Distance from the two-hand buttons to the danger area 
It is necessary to maintain a minimum distance between the buttons for the two-hand circuit and the danger area on the 
machine or plant so that, after the release of one or both buttons, the machine or plant can only be reached once the dange-

rous movement has been interrupted or completed. According to the standard EN 999, the distance is calculated with the 

following equation: 
                                                                                    S = (K · T) + C 
S: Minimum distance from the nearest pushbutton (two-hand button) to the danger area. 
K: Parameter in mm/s, derived from data on the approach speeds of the body or parts of the body, for two-hand circuits       
    1600mm/s. 
T: The overtravel of the overall system in seconds, that is the time from releasing the two-hand button to the end of the dan 
     gerous movement. 
C: Additional distance in mm that based on entry into the danger area prior to the triggering of the safety device. For twohand 
     circuits this is 250mm, this distance can also be set to 0mm given an adequate cover on the buttons, however then S     
     must be at least 100mm. 

Example 

The overtravel time for the entire system is 90ms. Then the above equation gives for the minimum distance: 
           S = (1600 mm/s · 0.09 s) + 250 mm 
           S = 144 mm + 250 mm = 394 mm 
 
If a suitable cover is used, S can be reduced to 144mm (see above). 