background image

1017 User Guide

1

1017 User Guide

Go to this device's product page [1]

Getting Started

Checking the Contents

You should have received:

A PhidgetInterfaceKit 0/0/8

A Mini-USB Cable

A Hardware mounting kit

In order to test your new Phidget you will also need:

A 9V battery

A battery connector

A 9V incandescent bulb with wires

Connecting the Pieces

1. Connect the negative (-) wire from the battery connector to one of the bulb wires.
2. Connect the positive (+) wire from the battery connector to the NO (normally open) connector on the

InterfaceKit.

3. Connect the other bulb wire to the 4A connector on the InterfaceKit.
4. Connect the InterfaceKit to your PC using the USB cable.

Testing Using Windows 2000 / XP / Vista / 7

Make sure you have the current version of the Phidget library installed on your PC. If you don't, follow these steps:

1. Go to the Quick Downloads section on the Windows page

2. Download and run the Phidget21 Installer (32-bit, or 64-bit, depending on your system)
3. You should see the   icon on the right hand corner of the Task Bar.

Running Phidgets Sample Program

Double clicking on the   icon loads the Phidget Control Panel; we will use this program to ensure that your new

Phidget works properly.

The source code for the 

InterfaceKit-full 

sample program can be found in the quick downloads section on the C#

Language Page. If you'd like to see examples in other languages, you can visit our Languages page.

Summary of Contents for 1017

Page 1: ...faceKit 4 Connect the InterfaceKit to your PC using the USB cable Testing Using Windows 2000 XP Vista 7 Make sure you have the current version of the Phidget library installed on your PC If you don t follow these steps 1 Go to the Quick Downloads section on the Windows page 2 Download and run the Phidget21 Installer 32 bit or 64 bit depending on your system 3 You should see the icon on the right h...

Page 2: ...bottom row shows the status of the request while the top row displays the status of the digital output as reported by the device 3 Move the positive wire from NO to NC normally closed The light is now on when the Digital box has no tick mark Clicking on the box turns the light off If you unplug the USB cable when the light is on it will stay on Testing Using Mac OS X 1 Go to the Quick Downloads se...

Page 3: ...lly closed terminal is the terminal connected to common when the relay coil is not powered When the relay coil is energized by the relay control circuit the electromagnetic field of the coil forces the switch element inside the relay to break its contact with the normally closed terminal and make contact with the normally open terminal The switch element would then connect the normally open termin...

Page 4: ...stant 8 Returns the number of digital outputs supported by this PhidgetInterfaceKit bool OutputState int OutputIndex get set Sets returns the state of a digital output Setting this to true will activate the output making the contact between Common and NO False is the default state Reading the OutputState immediately after setting it will not return the value set it will return the last state repor...

Page 5: ...ecting_The_Hardware jpg License unknown Contributors Mparadis File Ph jpg Source http www phidgets com wiki index php title File Ph jpg License unknown Contributors Mparadis File 1017_1_Control_Panel_Screen jpg Source http www phidgets com wiki index php title File 1017_1_Control_Panel_Screen jpg License unknown Contributors Mparadis File 1017_1_InterfaceKit_Screen jpg Source http www phidgets com...

Reviews: