User Information

  

H. ZANDER 

 GmbH & Co. KG • Am Gut Wolf 15 • D52070 Aachen • Tel +49 (0)241 9105010 • Fax +49 (0)241 91050138 

[email protected] • www.zander-aachen.de 

B01 

B101 

 

E61-137-00 

 

• 

2 start behaviors possible: 
- Monitored manual start 
-  Automatic start 

• 

Short circuit and earth fault monitoring 

• 

Up to PL e, SILCL 3, category 4 

• 

Version with higher DC breaking capacity possible

 

• 

It is not allowed to open the device, tamper with the de-
vice or bypass the safety devices. 

• 

All relevant safety regulations and standards are to be 
observed. 

• 

The overall concept of the control system in which the 
device is incorporated must be validated by the user. 

• 

Failure to observe the safety regulations can result in 
death, serious injury and serious damage. 

Correct Use

 

The SR3C is a universal emergency stop safety switching device 

with three safe relay outputs that can quickly and safely stop the 

moving parts of a machine or system in case of danger.  

Applications for the SR3C include single or dual-channel emer-

gency stop circuits and guard monitoring on machines and sys-

tems. 

Features

 

• 

3 safe, redundant relay outputs 
1 auxiliary contact (signaling contact) 

• 

Connection of: 

    -  Emergency stop buttons 
    -  Safety switches 
    -  Non-contact safety switches 
    -  OSSD-Outputs 

• 

Single and dual-channel operation possible 

• 

Feedback loop for monitoring downstream contactors or 
expansion modules 

• 

Cyclical monitoring of the output contacts 

• 

Indication of the switching state via LED 

Function 

The emergency stop safety switching device SR3C is de-
signed for safe isolation of safety circuits according to EN 
60204-1 and can be used up to safety category 4, PL e 
according to EN ISO 13849-1.

 

The internal logical system closes the safety contacts when 
the start button is pressed. 
If the safety switch is opened, the positively driven safety 
contacts are opened and safely switch the machine off. It is 
ensured that a single fault does not lead to a loss of the 
safety function and that every fault is detected by cyclical 
self-monitoring no later than when the system is switched off 
and switched on again.

 

Electrical  
Connection 

• 

When the 24V version is used, a control transformer 
according to EN 61558-2-6 or a power supply unit with 
electrical isolation from the mains must be connected. 

• 

External fusing of the safety contacts (6A slow-blow or 
8A quick-action or 10 A gG) must be provided. 

• 

A maximum length of the control lines of 1000 meters 
with a line cross section of 0.75 mm

2

 must not be ex-

ceeded. 

• 

The line cross section must not exceed 2.5 mm

2

• 

If the device does not function after commissioning, it 
must be returned to the manufacturer unopened. Ope-
ning the device will void the warranty. 

Installation 

As per EN 60204-1, the device is intended for installation in 
control cabinets with a minimum degree of protection of 
IP54. It is mounted on a 35-mm DIN rail according to DIN 
EN 60715 TH35. 

Safety  
Precautions 

• 

Installation and commissioning of the device must be 
performed 

only by authorized personnel

.

 

• 

Observe the country-specific regulations when installing 
the device. 

• 

The electrical connection of the device is only allowed to 
be made with the device isolated. 

• 

The wiring of the device must comply with the instruc-
tions in this user information, otherwise there is a risk 
that the safety function will be lost. 

Fig. 1 Block diagram SR3C 

SR3C, Order no. 472173 

Germanischer Lloyd 

certificate 32915-06HH 

Fig. 2  Installation / removal 

Fig. 3  Connections 

A1:  

Power supply 

A2 : 

Power supply 

S11:  

DC 24V control voltage  

S10:  

Control line  

S21: 

Start control line 

S13: 

Control line  

S14: 

Control line  

S12: 

Control line  

13-14: 

Safety contact 1 

23-24: 

Safety contact 2 

33-34: 

Safety contact 3 

41-42: 

Auxiliary contact  

Emergency Stop Safety Relay SR3C AC/DC24V 

(not for plug-in terminals) 

English translation 

Summary of Contents for SR3C

Page 1: ...ively driven safety contacts are opened and safely switch the machine off It is ensured that a single fault does not lead to a loss of the safety function and that every fault is detected by cyclical self monitoring no later than when the system is switched off and switched on again Electrical Connection When the 24V version is used a control transformer according to EN 61558 2 6 or a power supply...

Page 2: ...havior is set close the start button to close the safety contacts Fig 6 Monitored manual start It is monitored that the start button was opened before the emergency stop button closes Prerequisite operating voltage must not be interrupted Fig 7 Automatic start Max perm delay during closing of the safety switches on S12 and S13 S12 before S13 300 ms S13 before S12 any Warning Safety contacts switch...

Page 3: ... 107 electr 1 x 105 operating cycles Test voltage 2 5kV control voltage contacts Rated impulse withstand voltage leakage path air gap 4kV DIN VDE 0110 1 Rated insulation voltage 250V Degree of protection IP20 Temperature range 15 C to 40 C Degree of contamination 2 DIN VDE 0110 1 Overvoltage category 3 DIN VDE 0110 1 Weight approx 230g Mounting DIN rail according to EN 60715TH35 Note Additional da...

Page 4: ... Order no 472172 SR3C AC DC 24V fixed screw terminals Order no 472173 SR3C AC DC 24V high DC breaking capacity fixed screw terminals Order no 473172 SR3C AC DC 24V plug in terminals Order no 473173 SR3C AC DC 24V high DC breaking capacity plug in terminals Order no 472592 EKLS4 set of plug in screw terminals Order no 472593 EKLZ4 set of plug in tensile spring terminals Emergency Stop Safety Relay ...