background image

F-54

Enclosed Switch 

SHL

DC Operation

LED indicator is provided.
As a rectifier stack is incorporated, into the unit and no directionality
exists for connection of + and –, this type can also be operated on
AC.

Voltage ratings of LED indicators are as shown in the table below.

The Switch case has a protrusion to facilitate visual confirmation of
LED indicator.

Example:

Basic type:

SHL-Q2255-01MR

When placing your order for the molded terminal with an LED indica-
tor rated at 12 V, specify the model number as SHL-Q2255-01L2MR.

Contact Circuit

Precautions

Correct Use

Be sure to connect a fuse with a breaking current 1.5 to 2 times the
rated current to the Limit Switch in series in order to protect the Limit
Switch from damage due to short-circuiting.
When using the Limit under the EN ratings, use a gI or gG 10-A fuse
that conforms to IEC260.

Handling

When detaching the Terminal Protective Cover, insert a screwdriver
and apply a force in the opening direction. Do not use excess force to
remove the cover. Doing so may cause deformation in the fitting sec-
tion and reduce the holding force.

When mounting the Terminal Protective Cover to the case, align the
cover on the case and then press the cover down to mount it firmly. If
the cover is pressed down in an inclined position, rubber packing will
deform and thus affect the sealing capability.

Mounting

Secure the Switch with two M4 screws and washers. The tightening
torque applied to each terminal must be 1.18 to 1.37 N·m. Tighten
the screws to the specified torque. An excessive tightening torque
may damage the Switch and cause a malfunction.

When mounting the panel mount-type Switch with screws on a side
surface, remove the hexagonal nuts from the actuator.

Mounting Holes

When mounting the panel mount type (SHL-Q55, SHL-Q2255, or
SHL-Q2155) on a panel, tighten the hexagonal nuts of the actuator to
a torque less than 7.84 N·m.

Tightening Torque

A loose screw may result in a malfunction. Be sure to tighten each
screw to the proper tightening torque as shown below.

When wiring, use M3 round solderless terminals and apply insulation
shielding to the connections. Tighten the terminals screws to 0.24 to
0.44 N·m.

Operating Stroke

Ensure that the operating stroke for roller plunger models is within
the set position display. 

Type

Voltage rating

Lamp current

Internal 

resistance

L2

12 V

Approx. 2.4 mA

4.3 k

L3

24 V

Approx. 2 mA

10 k

L4

24 V

Approx. 1.2 mA

18 k

L5

48 V

Approx. 2.1 mA

22 k

Power supply*

Built-in switch

Load 

Resistor 

LED

*An external power supply can be used, eg. OMRON S8VS.

Screwdriver

Terminal Protective Cover

No.

Type

Torque

1

Terminal screw (M3 screw) 0.24 to 0.44 N·m

2

Panel mounting screw 
(M4 screw)

1.18 to 1.37 N·m

Two, 4.3-dia. or 
M4 screw holes

Operating stroke range

Reference

Summary of Contents for SHL -

Page 1: ...Standard Models 1 Actuator D Plunger Q Panel mount plunger Q22 Panel mount roller plunger Q21 Panel mount crossroller plunger W Short hinge lever W1 Hinge lever W2 Short hinge roller lever W21 Hinge...

Page 2: ...ay action hinge roller lever Agency Standard File No UL UL508 E76675 CSA CSA C22 2 No 14 LR45746 T V Rheinland EN60947 5 1 R9451332 Rated voltage Carry current Current Volt amperes Make Break Make Bre...

Page 3: ...tate current Micro Voltage Current Load Model Rated voltage Non inductive load Inductive load Inrush current Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO NC NO 125 VAC 10...

Page 4: ...e 1 000 VAC max 300 VDC max EN60947 5 1 Pollution degree operating environment 3 EN60947 5 1 Short circuit protective device SCPD 10 A fuse type gG IEC269 Conditional short circuit current 100 A EN609...

Page 5: ...M 1 2 NC 4 NO EN60947 5 1 Ambient temperature 5 C to 35 C Ambient humidity 40 to 50 Durability x 10 4 operations Switching current A Operating frequency 30 operations min cos 1 250 VAC Movable plunger...

Page 6: ...tainless steel pin plunger 9 6 15 15 16 9 7 8 dia see note Note Stainless steel pin plunger Panel Mount Plunger SHL Q55 SHL Q55 01 M14 1 Two hexagon nut thickness 2 5 width 17 9 6 15 15 16 9 11 dia 4...

Page 7: ...6 16 5 0 2 9 6 16 17 5 15 15 Hinge Lever SHL W155 SHL W155 01 Note Stainless steel lever t 1 see note 53R OP FP 13 24 3 5 16 9 9 6 16 6 8 21 16 15 15 16 5 0 2 Note Sintered stainless roller Short Hing...

Page 8: ...One way Action Short Hinge Roller Lever SHL W355 SHL W355 01 9 5 dia 4 8 see note OP FP 35 5R Operating direction 13 24 3 5 16 9 9 6 16 6 8 21 16 15 15 16 5 0 2 90 Note Stainless sintered roller One...

Page 9: ...and or EN IEC approved models are available The molded terminal model may be equipped with an operation indicator neon lamp or LED upon request to facilitate maintenance and inspection The operation i...

Page 10: ...tion rubber packing will deform and thus affect the sealing capability Mounting Secure the Switch with two M4 screws and washers The tightening torque applied to each terminal must be 1 18 to 1 37 N m...

Page 11: ...lowing diagram The above diagram is for standard conditions 5 C to 35 C 40 to 70 Since the values vary depending on the operating environ ment conditions contact your OMRON representative for further...

Page 12: ...t of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces...

Reviews: