Enclosed Switch
SHL
F-47
Lim
it
Switch
es
■
Ratings
Note: 1.
The above figures are for steady-state currents.
2.
Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.
Lamp load has an inrush current of 10 times the steady-state current.
4.
Motor load has an inrush current of 6 times the steady-state current.
Micro Voltage/Current Load Model
Rated voltage
Non-inductive load
Inductive load
Inrush current
Resistive load
Lamp load
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
125 VAC
10 A
1.5 A
3 A
2.5 A
15 A max.
250 VAC
10 A
1.5 A
2 A
1.5 A
480 VAC
2 A
---
---
---
8 VDC
10 A
2 A
5 A
2 A
14 VDC
10 A
2 A
5 A
2 A
30 VDC
5 A
1.5 A
1.5 A
1.5 A
125 VDC
0.4 A
0.4 A
0.05 A
0.05 A
250 VDC
0.2 A
0.2 A
0.03 A
0.03 A
Rated voltage
Non-inductive load
Resistive load
NC
NO
125 VAC
0.1 A
8 VDC
0.1 A
14 VDC
0.1 A
30 VDC
0.1 A