background image

Enclosed Switch

 

SHL

F-47

Lim

it 

Switch

es

Ratings

Note: 1.

The above figures are for steady-state currents.

2.

Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

3.

Lamp load has an inrush current of 10 times the steady-state current.

4.

Motor load has an inrush current of 6 times the steady-state current.

Micro Voltage/Current Load Model

Rated voltage

Non-inductive load

Inductive load

Inrush current

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

NC

NO

125 VAC

10 A

1.5 A

3 A

2.5 A

15 A max.

250 VAC

10 A

1.5 A

2 A

1.5 A

480 VAC

2 A

---

---

---

8 VDC

10 A

2 A

5 A

2 A

14 VDC

10 A

2 A

5 A

2 A

30 VDC

5 A

1.5 A

1.5 A

1.5 A

125 VDC

0.4 A

0.4 A

0.05 A

0.05 A

250 VDC

0.2 A

0.2 A

0.03 A

0.03 A

Rated voltage

Non-inductive load

Resistive load

NC

NO

125 VAC

0.1 A

8 VDC

0.1 A

14 VDC

0.1 A

30 VDC

0.1 A

Summary of Contents for SHL -

Page 1: ...Standard Models 1 Actuator D Plunger Q Panel mount plunger Q22 Panel mount roller plunger Q21 Panel mount crossroller plunger W Short hinge lever W1 Hinge lever W2 Short hinge roller lever W21 Hinge...

Page 2: ...ay action hinge roller lever Agency Standard File No UL UL508 E76675 CSA CSA C22 2 No 14 LR45746 T V Rheinland EN60947 5 1 R9451332 Rated voltage Carry current Current Volt amperes Make Break Make Bre...

Page 3: ...tate current Micro Voltage Current Load Model Rated voltage Non inductive load Inductive load Inrush current Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO NC NO 125 VAC 10...

Page 4: ...e 1 000 VAC max 300 VDC max EN60947 5 1 Pollution degree operating environment 3 EN60947 5 1 Short circuit protective device SCPD 10 A fuse type gG IEC269 Conditional short circuit current 100 A EN609...

Page 5: ...M 1 2 NC 4 NO EN60947 5 1 Ambient temperature 5 C to 35 C Ambient humidity 40 to 50 Durability x 10 4 operations Switching current A Operating frequency 30 operations min cos 1 250 VAC Movable plunger...

Page 6: ...tainless steel pin plunger 9 6 15 15 16 9 7 8 dia see note Note Stainless steel pin plunger Panel Mount Plunger SHL Q55 SHL Q55 01 M14 1 Two hexagon nut thickness 2 5 width 17 9 6 15 15 16 9 11 dia 4...

Page 7: ...6 16 5 0 2 9 6 16 17 5 15 15 Hinge Lever SHL W155 SHL W155 01 Note Stainless steel lever t 1 see note 53R OP FP 13 24 3 5 16 9 9 6 16 6 8 21 16 15 15 16 5 0 2 Note Sintered stainless roller Short Hing...

Page 8: ...One way Action Short Hinge Roller Lever SHL W355 SHL W355 01 9 5 dia 4 8 see note OP FP 35 5R Operating direction 13 24 3 5 16 9 9 6 16 6 8 21 16 15 15 16 5 0 2 90 Note Stainless sintered roller One...

Page 9: ...and or EN IEC approved models are available The molded terminal model may be equipped with an operation indicator neon lamp or LED upon request to facilitate maintenance and inspection The operation i...

Page 10: ...tion rubber packing will deform and thus affect the sealing capability Mounting Secure the Switch with two M4 screws and washers The tightening torque applied to each terminal must be 1 18 to 1 37 N m...

Page 11: ...lowing diagram The above diagram is for standard conditions 5 C to 35 C 40 to 70 Since the values vary depending on the operating environ ment conditions contact your OMRON representative for further...

Page 12: ...t of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces...