SGE/SCC
12
Installation
Safety edges must only be installed by authorized persons.
1.
To facilitate installation of the safety edge, the mounting base may
only be attached to even surfaces. If the safety edge is mounted in
a bend, the radius must not be less than the specified minimum.
2.
The mounting base must be fitted with countersunk screws or
rivets. A diameter of 4 mm is sufficient. The holes of 4.5 mm must
be evenly distributed over the entire length of the mounting base
with distances between them not exceeding 300 mm. They have
to be countersunk according to the screw size.
When using SGE-125, drill a pilot hole to the groove such that the
head of a countersunk screw can go through (approx. 8 mm).
3.
Pan- or round-head screws should not be used. Otherwise the
connecting wire in the mounting base could be damaged.
4.
In order to lead the connecting wire through the mounting base, an
8 mm hole has to be drilled in the appropriate place. Carefully
remove the burr from both sides.
5.
The connecting wire and the cable end with the terminal resistor
have to be placed in the mounting base.
6.
In order to make fitting the safety edge easier, the mounting base
and the safety edge should be sprayed with soapy water. Once the
soap suds have evaporated, the safety edge is firmly fitted in the
aluminum base. To prevent a subsequent slipping of the safety
edge, talcum powder, oils or similarly durable lubricants must not
be used.
7.
Safety edges with a C-base (SGE-365) have to be clipped with
one side into the mounting base. Then press in the complete c-
base. Pulling or pushing the safety edge into the mounting base
can cause damage to the safety edge and should be avoided at all
costs.
8.
Safety edges with T-bases (SGE-125/-225/-245/-245L) have to be
inserted from the side along the groove of the mounting base.
Any other methods of fastenings are only permitted on prior
agreement with the manufacturer.
For SGE-225/245 (L-shaped)
For SGE-365 (L-shaped)
For SGE-125
C-base
T-base