Characteristics
Force Distance
SGE-125
: : Characteristic Values for Test Speed
V
= 10 mm/s
Note:
Tested according to EN 1760-2, test object of
ϕ
80mm,
actuating point C3.
SGE-125
: Characteristic Values for Test Speed
V
= 100 mm/s)
Note:
Tested according to EN 1760-2, test object of
ϕ
80mm,
actuating point C3.
SGE-225: Characteristic Values for Test Speed
V
= 10 mm/s)
Note:
Tested according to EN 1760-2, test object of
ϕ
80mm,
actuating point C3.
SGE-225: Characteristic Values for Test Speed
V
= 100 mm/s)
Note:
Tested according to EN 1760-2, test object of
ϕ
80mm,
actuating point C3.
SGE-245: Characteristic Values for Test Speed
V
= 10 mm/s)
Note:
Tested according to EN 1760-2, test object of
ϕ
80mm,
actuating point C3.
SGE-245: Characteristic Values for Test Speed v = 100 mm/s)
Note:
Tested according to EN 1760-2, test object of
ϕ
80mm,
actuating point C3.
SGE-365: Characteristic Values for Test Speed
V
= 10 mm/s)
Note:
Tested according to EN 1760-2, test object of
ϕ
80mm,
actuating point C3.
SGE-365: Characteristic Values for Test Speed
V
= 100 mm/s)
Note:
Tested according to EN 1760-2, test object of
ϕ
80mm,
actuating point C3.
Force
(
N
)
Distance
(mm)
Force - C
u
r
v
e
S
w
itching - Point
Test Temperat
u
re +20°C
SGE-225: Characteristic
V
al
u
es for Test Speed
v
= 10 mm/s)
S
B
A
S
V
-250
N
S
V
-400
N
B1
B2
Safety
o
u
tp
u
t
Closed
Safety
o
u
tp
u
t
Open
Test Temperature
+20°C
Actuating Force F
A
(N)
42
Actuating Distance S
B
(mm)
2.6
Overtravel Distance
Sv at 250N in mm
8.1
Overtravel Distance
Sv at 400N in mm
9.5
Test Temperature
+20°C
Actuating Force F
A
(N)
43
Actuating Distance S
B
(mm)
6.4
Overtravel Distance
Sv at 250N in mm
7.7
Overtravel Distance
Sv at 400N in mm
8.6
Test Temperature
+20°C
Actuating Force F
A
(N)
57
Actuating Distance S
B
(mm)
3.9
Overtravel Distance
Sv at 250N in mm
2.3
Overtravel Distance
Sv at 400N in mm
6.7
Test Temperature
+20°C
Actuating Force F
A
(N)
63
Actuating Distance S
B
(mm)
4.4
Overtravel Distance
Sv at 250N in mm
2.7
Overtravel Distance
Sv at 400N in mm
7.2
Test Temperature
+20°C
Actuating Force F
A
(N)
68
Actuating Distance S
B
(mm)
7.4
Overtravel Distance
Sv at 250N in mm
15.8
Overtravel Distance
Sv at 400N in mm
18.3
Test Temperature
+20°C
Actuating Force F
A
(N)
83
Actuating Distance S
B
(mm)
7.8
Overtravel Distance
Sv at 250N in mm
15.2
Overtravel Distance
Sv at 400N in mm
17.7
Test Temperature
+20°C
Actuating Force F
A
(N)
78
Actuating Distance S
B
(mm)
5.2
Overtravel Distance
Sv at 250N in mm
29.8
Overtravel Distance
Sv at 400N in mm
33.8
Test Temperature
+20°C
Actuating Force F
A
(N)
107
Actuating Distance S
B
(mm)
6.2
Overtravel Distance
Sv at 250N in mm
28.3
Overtravel Distance
Sv at 400N in mm
32.7