Safety Precautions

Warning Indications

Meaning of Product Safety Symbols

Product failure may result in fire or electric shocks.
Be sure to use the recommended circuit breaker or 
fuse.

The electrical wire may come out and an electric shock may 
be caused. Insert the solid wire or ferrule straight into the 
terminal block until the end touches the terminal block.

Minor electric shock, fire, or Product failure may 
occasionally occur. Do not disassemble, modify, or repair 
the Product or touch the interior of the Product.

Minor burns may occasionally occur. Do not touch 
the Product while power is being supplied or 
immediately after power is turned OFF.

Minor injury due to electric shock may occasionally 
occur. Do not touch the terminals while power is 
being supplied.

Minor electric shock, fire, or Product failure may occasionally 
occur. Do not allow any pieces of metal, conductors, or 
cuttings from installation work to enter the Power Supply.

If the circuit breaker has tripped, or the fuse has 
blown, there could be a severe failure in the Power 
Supply. Do not turn the input ON again.

Ambient Operating and Storage Environments

• Store the Power Supply at a temperature of -40 to +85°C and a 

humidity of 95% or less.

• Do not use the Power Supply in areas outside the derating curve 

as doing so may result in internal parts occasionally deteriorating 
or being damaged.

• Use the Power Supply at a humidity of 95% max.
• Do not use the Power Supply in locations subject to direct sunlight.
• Do not use locations where liquids, foreign matter, or corrosive 

gases may enter the interior of the Product.

Installation Environment

• Do not use the Product in locations subject to shocks or vibrations. 

In particular, install the Power Supply as far away as possible from 
contactors or other devices that are a vibration source.

• Install the Power Supply well away from any sources of strong, 

high-frequency noise and surge.

Mounting

• Take adequate measures to ensure proper heat dissipation to 

increase the long-term reliability of the Power Supply.
Be sure to allow convection in the atmosphere around devices 
when mounting. Do not use in locations where the ambient 
temperature exceeds the range of the derating curve.

• When cutting out holes for mounting, make sure that cuttings do 

not enter the interior of the Power Supplies.

• The internal parts may occasionally deteriorate and be broken due 

to adverse heat radiation. Do not loosen the screws on the Power 
Supply.

• S8VK-WA can be used in combinations with a horizontal 

separation of less than 15 mm (front, side-by-side mounting) only 
in cases of the same model being used.
In such cases, use the product in accordance with a derating curve 
with a horizontal separation of less than 15 mm.

Indicates a potentially hazardous situation 
which, if not avoided, will result in minor or 
moderate injury, or may result in serious 
injury or death. Additionally, there may be 
significant property damage.

Indicates a potentially hazardous situation 
which, if not avoided, may result in minor or 
moderate injury or in property damage.

Precautions 

for Safe Use

Supplementary comments on what to do or 
avoid doing, to use the product safely.

Precautions 

for Correct 

Use

Supplementary comments on what to do or 
avoid doing, to prevent failure to operate, 
malfunction or undesirable effect on product 
performance.

Caution against electric shock
Used to warn of the risk of electric shock under 
specific conditions.

Caution against high temperatures
Used to warn of the risk of minor injury caused by 
high temperatures.

No disassembly
Use to indicate prohibition when there is a risk of 
minor injury from electrical shock or other source if 
the product is disassembled.

General instructions
Used for general mandatory action precautions for 
which there is no specified symbol.

WARNING

CAUTION

WARNING

CAUTION

Precautions for Safe Use

*

2

*

2

*

1

*

3

*

3

*

1

*

1

*

1

*

1

*

1

*1.

Convection of air

*2.

Vertical separation: 23 
mm or more

*3.

Horizontal separation: 
15mm or more
(Standard mounting)
Horizontal separation: 
Less than 15 mm
(Front, side-by-side 
mounting)

(B) Face-up mounting

(A)  Standard (Vertical) 

mounting

(C) Front, Side-by-side 

mounting

Summary of Contents for S8VK-WA Series

Page 1: ...put UL 121201 acquired Certification for 3 000 m altitude UL EN IEC 62368 1 EN 50178 EN 62477 1 1 Conforms to EN IEC 61558 2 16 Coated PCBs for Better Resistance to Environment Warranty Five years 3 1...

Page 2: ...Maximum boost current Model 240 W Three phase single phase 200 to 240 VAC Allowable range Three phase single phase 170 to 264 VAC 240 to 350 VDC 24 V 10 A 15 A S8VK WA24024 480 W 24 V 20 A 30 A S8VK W...

Page 3: ...fer to Overload Protection on page 5 Overvoltage protection Yes 130 or higher of rated output voltage power shut off shut off the input voltage and turn on the input again Refer to Overvoltage Protect...

Page 4: ...details Standard Compliance To comply with PELV output requirements for EN IEC 60204 1 ground the negative side of the output V to a protective earth PE EN IEC 61558 2 16 The S8VK WA was designed bas...

Page 5: ...90 of the rated output voltage and the internal MOS FET relay is conducted turned ON Note 1 The output voltage may be generated even if the indicator does not light Be sure to check the output voltag...

Page 6: ...th less load or larger output capacity The product may have failed or the overvoltage protection may have been activated for the product To check for overvoltage protection turn the input power OFF an...

Page 7: ...oothing circuit Harmonic current suppression circuit DC OK COM DC OUTPUT L1 1 INPUT L1 2 L2 1 L2 2 L3 2 L3 1 out I 100 S8VK WA48024 480 W Overcurrent detection circuit Current detection circuit Smooth...

Page 8: ...V2 10 V1 11 V2 12 V3 13 INPUT OK Indicator INPUT OK Green Lights up when the input voltage exceeds the lower limit value of the permissible range 14 Iout 100 Indicator Iout 100 Yellow The Iout 100 In...

Page 9: ...s applied C Front side by side mounting This Power Supply can be used at an altitude of up to 3 000 m Between 2 000 and 3 000 m derate the load according to the following derating curve 240 W 480 W Ho...

Page 10: ...W20F Front mounting bracket For 480 W models S82Y VKW40F 1 1 5 2 8 0 max when sliding 5 17 3 117 111 4 5 4 15 8 54 4 53 8 5 4 6 5 0 55 19 8 1 2 0 6 121 4 1 55 1 0 6 124 1 10 S8VK WA24024 5 2 8 0 max w...

Page 11: ...cted to sliding to either side attach an End Plate PFP M on each side of the Unit Mounting Rail Material Aluminum PFP 100N PFP 50N 4 5 15 25 25 10 10 1 000 500 25 25 15 5 35 0 3 7 3 0 15 27 0 15 1 ind...

Page 12: ...dissipation to increase the long term reliability of the Power Supply Be sure to allow convection in the atmosphere around devices when mounting Do not use in locations where the ambient temperature...

Page 13: ...move the sheet covering the S8M for machining before power ON so that it does not interfere with heat dissipation If there is a possibility of vibration or shock please use wires and stranded wires wi...

Page 14: ...t flow Duty 30 Do not allow the peak current to continue for more than 10 seconds Do not allow the duty to exceed 30 The Power Supply may be damaged Ensure that the average current of one cycle of the...

Page 15: ...ge of 25 V max Adjust the output voltage difference of each Power Supply to 50 mV or less using the output voltage adjuster V ADJ There is no current balancing function for S8VK X A high output voltag...

Page 16: ...e screwdriver and pull out the Block Connecting Wires to the Push In Plus Terminal Block Part Names of the Terminal Block Connecting Wires with Ferrules and Solid Wires Insert the solid wire or ferrul...

Page 17: ...nals COM Terminals Note 1 Make sure that the outer diameter of the wire is smaller than the inner diameter of the insulating sleeve of the recommended ferrule 2 Make sure that the ferrule processing d...

Page 18: ...he overload protection or overvoltage protection has operated The internal protection may operate if a large amount of surge voltage such as a lightning inrush is applied to the input In case there is...