background image

1

Switching Power Supply

S8PS

The Most Compact DIN-track-mounting Switching Power Supplies Ever with
Capacities Up to 600 W

Power range from 50 W up to 600 W.
Open-frame and covered types available.
Easily mounted to DIN track with provided
Mounting Brackets.
Models with Front-mounting Bracket available.
Conforms to EMC standards: EN50081-1,
EN50082-2, and EN61000-3-2.
Maintenance-free up to 300 W due to natural
ventilation.
Protection-ON alarm indicator shows valuable
protection functions in action (300-/600-W
models).
AC universal input: 100 to 240 VAC
Approved by UL/CSA standards, EN60950
(IEC950), and VDE0160.
Six-language instruction manual provided.
Life expectancy of 10 years min.
Finger protection terminal block meets
VDE0106/P100. (Covered type)

W

RC

Ordering Information

 S8PS

Configuration

Input voltage

Power ratings

Output voltage

Output current

Front-mounting

Bracket

DIN Track

Mounting Bracket

Covered type

100 to 240 VAC

50 W

5 V

10 A

S8PS-05005C

S8PS-05005CD

Co e ed y e

00 o

0

C

50

12 V

4.2 A

S8PS-05012C

S8PS-05012CD

24 V

2.1 A

S8PS-05024C

S8PS-05024CD

100 W

24 V

4.5 A

S8PS-10024C

S8PS-10024CD

150 W

24 V

6.5 A

S8PS-15024C

S8PS-15024CD

300 W

24 V

14 A

S8PS-30024C

S8PS-30024CD

600 W

24 V

27 A

S8PS-60024C

---

Open-frame type

100 to 240 VAC

50 W

5 V

10 A

S8PS-05005

S8PS-05005D

O e

a e y e

00 o

0

C

50

12 V

4.2 A

S8PS-05012

S8PS-05012D

24 V

2.1 A

S8PS-05024

S8PS-05024D

100 W

24 V

4.5 A

S8PS-10024

S8PS-10024D

150 W

24 V

6.5 A

S8PS-15024

S8PS-15024D

Model Number Legend:

S8PS-

jjjjjjj

1

2

3

1.

Power Ratings

050:

50 W

100:

100 W

150:

150 W

300:

300 W

600:

600 W

2.

Output Voltage

05:

5 V

12:

12 V

24:

24 V

3.

Configuration

C:

Covered type with Front-mounting Bracket

D:

Open-frame type with DIN Track Mounting Bracket

CD:

Covered type with DIN Track Mounting Bracket

None: Open-frame type with Front-mounting Bracket

Summary of Contents for S8PS Series

Page 1: ...Power ratings Output voltage Output current Front mounting Bracket DIN Track Mounting Bracket Covered type 100 to 240 VAC 50 W 5 V 10 A S8PS 05005C S8PS 05005CD Co e ed y e 00 o 0 C 50 12 V 4 2 A S8PS...

Page 2: ...s2 approx 30G 3 times each in X Y and Z directions Output indicator Yes green Terminal screw tightening torque 1 08 N S m 11 kgf S cm see note 2 Electromagnetic interference Conforms to FCC Class B E...

Page 3: ...on 600 W Model 20 mm min 20 mm min 20 mm min 20 mm min 30 mm min 30 mm min 20 mm min 20 mm min 30 mm min 30 mm min 20 mm min 20 mm min 20 mm min 20 mm min 20 mm min 20 mm min 50 to 150 W Model Natural...

Page 4: ...ercurrent condition continued otherwise the internal elements of the S8PS may be dam aged or broken Overvoltage Protection The Power Supply is provided with an overvoltage protection func tion that pr...

Page 5: ...hing circuit Detector Control circuit Overload detection circuit Overload detection circuit Harmonic current control Smooth ing Overload detection circuit Overload detection circuit Rectifier smoothin...

Page 6: ...h 6 max Front mounting Bracket for 50 W Models Mounting Holes Using the Mounting Bracket Attach the Mounting Bracket to the panel and loosely tighten the two screws Insert the projected parts of the B...

Page 7: ...ounting Bracket for 100 150 W Models Dimensions with Mounting Bracket Using the Mounting Bracket S8PS 30024C 300 W Eight M4 depth 8 max also for the opposite side Mounting holes also on opposite side...

Page 8: ...our M4 depth 8 max 300 W models 600 W models Four M4 Four M4 10 dia Two 5 dia 600 W models Note Mount the Unit 21 6 mm away from the mounting surface in order to provide air ventilation on the rear si...

Page 9: ...y Unit when the Unit is shipped S8PS 10024D 100 W S8PS 10024CD 100 W S8PS 15024D 150 W S8PS 15024CD 150 W Five M4 terminal screws 3 5 dia 11 5 max 5 6 With slide 9 max Five M4 terminal screws 4 5 dia...

Page 10: ...Order Separately PFP 100N PFP 50N 4 5 15 25 25 25 25 10 10 1 000 500 see note 7 3 0 15 35 0 3 27 0 15 1 4 5 15 25 25 25 25 15 10 10 1 000 35 0 3 27 24 16 29 2 1 1 5 PFP 100N2 15 5 see note Note The va...

Page 11: ...been turned OFF Doing so may result in electric shock due to a residual voltage Do not touch the S8PS or heat radiation fin while the power is being supplied or immediately after the power is turned...

Page 12: ...dust As a preventive maintenance measure replace the fan within two years if it is used at an ambient temperature of 40 C Fans are available as replacements Model S82Y JFAN Fan Set Fan above four M4 x...

Reviews: