3
36
NP Introduction Manual
3-2 Wiring Devices
3
Mo
unt
ing an
d Wi
rin
g
3-2 Wiring Devices
This section tells about NP and CP1L wiring.
■
Power
1.
Connect a 24VDC power supply to the power input terminals.
Note
• Use a twisted pair cable, more than 2mm
2
in diameter to connect the power.
• Do not connect an AC power supply to the power terminals.
• Use a DC power supply with low voltage fluctuation.
■
Ground
Do not ground if:
• The NP and host are far from each other, and a single point ground is not
possible.
• The NP is mounted on the same panel as noise sources such as motors and
inverters.
When there is a ground potential difference between the NP and host (PLC),
connect them with a grounding wire.
1.
Connect to a single point ground from the functional ground terminal [
]
on the NP.
Note
Ground correctly to prevent malfunctions caused by noise.