4-4 Creating Screens
4
4
90
NP Introduction Manual
C
rea
ti
ng
S
c
re
e
n
s
●
Fixed Object (Text)
Create the "I/O Check" and "TIM0" text objects.
For details, refer to
[01 Waiting]
.
Use these settings.
I/O Check
* Select [Bold] and [Center] from the toolbar.
TIM0
* Select [Bold] and [Center] from the toolbar.
●
Input (Numeric Input)
1.
Select [Objects] - [Input] - [Numeric Input] from the main menu. Move the
mouse cursor to the workspace.
The cursor will change shape to [+].
2.
Move the cursor.
An input frame will show.
3.
Set the numeric input properties.
Item
Setting
Label
I/O Check*
Label Size
24
Label Color
(Black)RGB(16,16,16)
Foreground Color
(White)RGB(255,255,255)
Item
Setting
Label
TIM0*
Label Size
32
Label Color
(Black)RGB(16,16,16)
Foreground Color
(White)RGB(255,255,255)
Item
Setting
Write Address
SERIALA:TIM00000
Read Address
SERIALA:TIM00000
Label Size
40
Border Color
(Black)RGB(16,16,16)
Foreground Color
(White)RGB(255,255,255)
Style
Standard
Leading Zero
Yes
Detail
[Input Value] dialog box (Data Format: BCD)