6. EtherNet/IP Settings
17
6.4. Tag Set
The settings of a tag set to use tag data links are shown below.
Set the data in the tag set in ascending order of the OUT No. or IN No. as shown below.
■ Output Area (Controller → Code
reader)
■ Input Area (Controller ← Code
reader)
6.5. Tag Data Link Table
The contents of the tag data link table (connection settings) are shown below.
The values shown in the red frames are the values defined in the EDS file of the code reader.
Connection
Name
Connection I/O Type
RPI (ms)
Timeout
default_001
Input 1 Decode
10.0
RPI x 32
Connection
I/O Type
Input/
Output
Target Variable
Size
(bytes)
Originator
Variable (Tag set
name)
Size
(bytes)
Connection
Type
Input 1
Decode
In
103
500
EIPInput
500
Point to
Point
connection
Out
197
4
EIPOutput
4
Point to
Point
connection
Originator Variable (Tag set name)
Data size (bytes)
EIPOutput
4
OUT No. Global Variable Name (Tag name)
Data size (bytes)
1
EIPOutput
4
Originator Variable (Tag set name)
Data size (bytes)
EIPInput
500
IN No.
Global Variable Name (Tag name)
Data size (bytes)
1
EIPInput
500
Summary of Contents for MicroHAWK V320-F