![Omron MicroHAWK V320-F Connection Manual Download Page 10](http://html.mh-extra.com/html/omron/microhawk-v320-f/microhawk-v320-f_connection-manual_741423010.webp)
5. Applicable Devices and Device Configuration
9
• Configuration with V430-F
Manufacturer
Name
Model
Version
OMRON
NX Series CPU Unit
(Built-in EtherNet/IP Port)
NX1P2-9024DT
Ver. 1.16
OMRON
Switching hub
W4S1-05C
OMRON
Sysmac Studio
SYSMAC-
SE2□□□
Ver. 1.28
OMRON
Sysmac Studio Project File
OMRON_V430_NX_EIP_
V101.csm2
Ver. 1.00
PC (OS: Windows 10)
LAN cable (STP (shielded, twisted-
pair) cable of Ethernet category 5
or higher)
OMRON
Code reader
V430-F000M12M-SRX
Ver. 2.1.0
OMRON
I/O Cable
V
430-W8-3M
OMRON
Ethernet cable
V
430-WE-3M
---
24 VDC power supply
---
V430-F000M12M-SRX
I/O Cable
V430-W8-3M
24 VDC power supply
LAN cable
NX1P2-9024DT
(Built-in EtherNet/IP Port)
Switching hub
W4S1-05C
PC
(Windows 10,
with Sysmac
Studio installed)
Ethernet cable
V430-WE-3M
24 VDC power supply
Summary of Contents for MicroHAWK V320-F