K8AC-H

17

Parameter List

The setting items in each mode are called “parameters.” 

Parameters can be switched by using the 

M

 key.

Power supply voltage 

measurement value

*

1

Voltage fluctuation 

compensation standard value

Number of 

CT passes 1

CT ratio 1

Number of 

CT passes 2

CT ratio 2

*

3

Parameter Display 

: Displayed for all models and settings.
: May not be displayed depending on the model or settings.

Setting change protection 

*

3

*

3

*

3

*

2

*

2

*

4

Voltage fluctuation 

compensation standard value

Setting 1 for number of 

effective digits to be displayed 

after the decimal point

Setting 2 for number of 

effective digits to be displayed 

after the decimal point 

init

sini

pini

hys1

hys2

gate

comp

stim

odly

soft

ssht

sopn

hrst

hral

msmd

dsel

psmd

pstm

dsmd

dsrf

u no

 bps

 len

sbit

nct1

ctr1

ndp1

nct2

ctr2

ndp2

prty

goht

al-1

al-2

ct 1

ct 2

sce 

max1

min1

max2

min2

maxs

isc2

isc1

otim

memo

acnt

min5

1234

VfcV

amoV

aspt

wtpt

test

g-lV

sdly

sglV

cyct

Heater 1 current

Heater 2 current

Heater 1

maximum current

Heater 1

minimum current

Heater 2

maximum current

Heater 2

minimum current

Maximum power

supply voltage

(Processing value

display status)

Heater 2 input shift

display current

Heater 1 input shift

display current

Minimum power

supply voltage

Number of

alarm outputs

Processing value

for alarm output

RUN time

Password for

moving to Set

Mode: 0169

Burnout alarm

setting value 1

Heater layer short circuit

detection function

SSR open circuit

detection function

SSR short circuit

detection function

Output ON-delay time

Soft startup time

Startup lock time

Gate input function

Alarm hysteresis 2

Alarm hysteresis 1

Processing value

initialization

All initialization

Set value initialization

Heater control

method

Switchable

display

Power save

mode

Power save 

mode standby 

time

Display mode

Display

refresh time

Unit number

Baud rate

SSR ON delay

SSR operation 

gate current level

Cycle time

Data length

Stop bits

Parity bit

Gate OFF

output hold time

Protection Mode

Adjust Mode

Run Mode

Measurement

parameters

Set Mode

Setting change protection

1 s min.

1 s min.

1 s min.

3 s min.

Po

w

er  ON

5 s  min.

Burnout alarm

setting value 2

1 s min.

1 s min.

1 s min.

Test Mode

Gate Mode

1 s min.

An alarm is output if 

the test value falls 

below the burnout 

alarm value 1 setting.

Alarm or detection is 

stopped if the gate 

current value falls 

below the set value.

Note: 

Displayed only for 

the K8AC-H2

@@@

Heater layer short circuit

alarm set value

*1.

Displayed when the Selectable Protection Level parameter is set to 0.

*2.

Displayed by the K8AC-H

@@

P

@

-FLK.

*3.

If more than five minutes elapses with no operations performed in Protection Settings Mode, Adjust Mode, Set Mode, or for a measurement 

parameter, the status will return automatically to the processing value display. 

If this occurs while settings are in progress, it may cause unintended operations to be performed in Run Mode (i.e., with measurement values 

displayed). Be careful not to allow this to happen.

*4.

Displayed by the K8AC-H

@@

C

@

-FLK.

Summary of Contents for K8AC-H Series

Page 1: ...nitor for element burnouts on heaters controlled with power regulators that used a three alarm method Normal monitoring is not possible for circuits that use a power regulator with a six alarm method...

Page 2: ...re linked with the control output value from the temperature controller Compatible with Gradient Settings of Power Controllers When using gradient settings with a power controller set a gate current l...

Page 3: ...tput specifi cations Com munica tions output Current input range 0 200 to 2 200 A 2 00 to 22 00 A 20 0 to 200 0 A 100 to 240 VAC ON OFF control SSR control Two current inputs for either single phase o...

Page 4: ...ut impedance 4 k min Cyclic and phase con trol 4 to 20 mA DC Burnout detection is possible for an input of 7 mA or greater Input impedance 50 max Outputs Relay contact outputs K8AC H C FLK One SPDT re...

Page 5: ...als and output terminals Dielectric strength 2 000 V for 1 min Between terminals and case Between power supply terminals CT primary terminals and gate input terminals communications terminals Between...

Page 6: ...VAC 0 3 A 30 VDC 1 A Maximum contact voltage 125 VAC 60 VDC Maximum contact current 1 A Maximum switching capaci ty 37 5 VA 30 W Minimum applicable load failure rate P value refer ence value 5 VDC 10...

Page 7: ...ct to the operating power supply All models 3 to 4 5 to 6 Outputs Outputs SSR open or short circuit detection results Outputs heater burnout or layer short circuit detection results K8AC H2 N transist...

Page 8: ...CTs for three phase heaters For three phase heaters always set the burnout alarm set values for both CT1 and CT2 5 6 3 4 Transistor Output K8AC H2 N FLK CT2 CT1 3 7 8 9 10 11 12 13 14 1 2 RS 485 X 4 5...

Page 9: ...ransistor Output K8AC H2 N FLK Heater Power supply Power Regulator Temperature Controller 4 to 20 mA current output Operation Description If the heater current detected at either CT1 or CT2 falls belo...

Page 10: ...o after one heater burns out with the current prior to the burnout i e the normal current taken as 1 3 In actual operation there may be effects from factors such as load heater imbalances so conduct a...

Page 11: ...s output accordingly SSR Short Circuit Detection If current is measured when there is no gate input an SSR short circuit error is detected and an alarm is output SSR Open Circuit Detection If current...

Page 12: ...Short Open Circuit Alarm Using the Power Regulator s Gradient Settings The power regulator s gradient settings can be used to prevent malfunction by setting the operation gate current level The relati...

Page 13: ...or over OFF for less than 4 mA SSR SSR error Lights when an SSR error occurs open or short circuit OFF when SSR is normal ALM Alarm Lights for heater burnout or overcurrent OFF at all other times Up k...

Page 14: ...pe P should be selected Type P is also selected for cyclic control Select the appropriate relay or transistor output specifications depending on the application K8AC H Parameter Settings Procedure Onl...

Page 15: ...freshed each time an alarm is output and it is saved in non volatile memory The value is saved when power is interrupted The number of outputs is not counted for the test function After counting to 99...

Page 16: ...r at least 1s Press the L key for at least 1 s Press the S key for at least 1 s Press the L key for at least 1s When the key is released Press the S key for at least 1 s Press the L and M keys Press t...

Page 17: ...layer short circuit detection function SSR open circuit detection function SSR short circuit detection function Output ON delay time Soft startup time Startup lock time Gate input function Alarm hyst...

Page 18: ...99 9 s 0 0 OFF SSR Short Circuit Detection Turns the SSR short circuit detection function ON and OFF ssht ON OFF OFF SSR Open Circuit Detection Turns the SSR open circuit detection function ON and OFF...

Page 19: ...te current level Sets the gate current level for SSR operation This setting is valid only when cyclic or phase control is selected as the heater control method sglv 4 0 to 20 mA 7 0 mA Cycle time 3 Se...

Page 20: ...ntact Approx 3 dia 18 22 Approx 6 dia Plug Contact Lead Plug 100 15 30 30 5 Two M3 Depth 4 max 12 dia 40 40 5 15 Current Transformer K8AC CT200 Pre wired Leads Current Transformer K8AC CT200L 1 8 76 4...

Page 21: ...o can cause unintended operation and may result in accident or corruption of the product 3 Do not use thinner or similar solvent for cleaning Use commercial alcohol 4 When discarding properly dispose...

Page 22: ...larm of the K8AC H P FLK when phase control is used Set the burnout alarm value of the K8AC H P FLK based on the current measurement value with the heater output at 100 This is because the burnout det...

Page 23: ...RODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR A...

Page 24: ...em as a whole has been designed to address the risks and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system Authorized Distributor In...

Reviews: