117
Terminal
number
Use
Signal
direction
Signal name
36
LL
Output
LL output (See note 2.)
37
COM
Output
GND:VO (See note 1.)
Note
1. Terminals 1, 25, and 37 have the same COM.
2. Refer to
2-3 Output Board
for comparative outputs.
Applicable Connectors
Use the connector provided with the K3NR or an equivalent connector for the
cable connecting to the BCD output connector.
The following connectors are provided with the K3NR.
Plug:
XM2A-3701 (OMRON)
Hood:
XM2S-3711 (OMRON)
The depth required for the installation of the K3NR is 200 mm min. in consider-
ation of the space required by the cable.
Connecting Conditions
Refer to the following for the connecting conditions of each I/O. Refer to
2-3
Out-
put Block
for output signals HH through LL.
•
Input
Input current with no voltage input:
10 mA
Signal level
ON voltage:
1.5 V max.
OFF voltage:
3 V min.
•
Output
Rated load voltage:
24 VDC
Rated load current:
10 mA
Current leakage:
10
µ
A max.
Connectors
Section 7-1