background image

K3NC

K3NC

3

3

CHARACTERISTICS

Input signal

No-voltage contact (30 Hz max., ON/OFF pulse width: 15 ms min.)
Voltage pulse (50 kHz max., ON/OFF pulse width: 9

µ

s min., ON voltage: 4.5 to 30 V/OFF

voltage:

--30 to 2 V)

Open collector (50 kHz max., ON/OFF pulse width: 9

µ

s min.)

Connectable Sensors
ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current
Transistor input: Must have switching capacity of 20 mA min.
Contact input: Must be able to dependably switch a load current of 5 mA max.

Input mode

Up/Down B (individual inputs), Up/Down C (phase difference inputs)

Output mode

ALL-H/ALL-L

Max. displayed digits

5 digits (--19999 to 99999)

Display

7-segment LED

Polarity display

“--” is displayed automatically with a negative input signal.

Zero display

Leading zeros are not displayed.

Prescale function

Programming via front-panel key inputs. (0.0001 x 10

--9

to 9.9999 x 10

9

, decimal point can be

set freely)
Can be set using prescale value teaching.

External control

RESET: 16 ms max. (external reset signal)
COMPENSATION: 16 ms max. (external compensation signal)
BANK 1, 2: 100 ms max. (bank switching time)

Up to 4 set value or prescale value banks available

Other functions

Variable linear output range (for models with linear outputs only)
Remote/Local processing (available for communications output models only)
Counting value reset with front panel keys
Security
Memory power failure

Output configuration

Relay contact output (5 outputs)
Transistor output (NPN and PNP open collector), BCD (NPN open collector)
Parallel BCD (NPN open collector) + transistor output (NPN open collector)
Linear output (4 to 20 mA, 1 to 5 V) + transistor output (NPN open collector)
Communication functions (RS-232C, RS-485, RS-422)
Communication functions (RS-232C, RS-485, RS-422) + transistor output (NPN open
collector)

Delay in comparative outputs

1 ms max. (at transistor output),
10 ms max. (at relay output)

Enclosure rating

Front panel

NEMA4 for indoor use (equivalent to IP66)

g

Rear case

IEC standard IP20

Terminals

IEC standard IP00

Memory protection

Non-volatile memory (EEPROM) (possible to rewrite 100,000 times)

Summary of Contents for K3NC

Page 1: ...ication Boards See page 155 3 BASE UNIT Model Supply voltage Applicable output boards Part number y g Input type NPN Voltage pulse PNP Basic model 100 to 240 VAC K31 C1 C2 C5 K31 T1 T2 K31 B2 B4 K31 L...

Page 2: ...each in X Y and Z directions Ambient t t Operating 10 to 55 C 14 to 131 F with no icing temperature Storage 20 to 65 C 4 to 149 F with no icing Ambient humidity Operating 25 to 85 with no condensation...

Page 3: ...aching External control RESET 16 ms max external reset signal COMPENSATION 16 ms max external compensation signal BANK 1 2 100 ms max bank switching time Up to 4 set value or prescale value banks avai...

Page 4: ...y status Indicates which comparative set value is currently on the SV display 5 ESC Key Used to return to the RUN mode from the Setting Protect or Maintenance mode 6 Mode Key Used to enter the Setting...

Page 5: ...set value OUT2 of bank 1 Enter set value OUT3 of bank 1 Enter set value OUT4 of bank 1 Enter set value OUT5 of bank 1 Note The above is an example when the bank number is set to 1 Display prescaling...

Page 6: ...For example the system shown in the illustration outputs 250 pulses when the object is advanced 0 5 m To enable the K3NC to display PPPP P mm obtain the advanced length of the object per pulse from t...

Page 7: ...T is lit when a RESET input is ON Note External reset minimum signal width 16 ms COMPENSATION Resets the present counting value to the compensation value at the rising edge of a compensation input In...

Page 8: ...ee Note While the reset signal is ON the counting value will return to zero When the compensation signal is ON the K3NC will be in counting operation starting with the preset compensation value Depend...

Page 9: ...ing charts Signal No voltage input H Short circuit L Open 3 BLOCK DIAGRAM Input circuit Power supply for sensor Sensor A Sensor B GND Control input Control input circuit Power supply circuit Control p...

Page 10: ...3 K3NC Panel Cutouts 92 14 2 8 2 PV Display OUT5 OUT4 OUT3 OUT2 OUT1 RESET OUT 1 2 3 4 5 91 3 58 44 1 73 96 3 78 112 4 41 48 1 89 90 3 54 2 2 0 09 43 1 69 12 4 0 49 130 5 12 75 min 2 95 120 min 4 72 4...

Page 11: ...pecifications subject to change without notice Printed in U S A OMRON ELECTRONICS INC One East Commerce Drive Schaumburg IL 60173 NOTE DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters to inc...

Page 12: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Omron K3NC NB2A...

Reviews: