F-8

1/32 DIN Digital Panel Meter 

K3GN

Input/Output Ratings

Relay Contact Output

(Incorporating G6K Relays)

Transistor Output

Communications Specifications

Linear Output

Item

Resistive load (cos

φ

 = 1)

Rated load

1 A at 30 VDC

Rated through current

1 A max. (at COM terminal)

Max. contact voltage

60 VDC

Max. contact current

1 A (at COM terminal)

Max. switching capacity

30 VA

Min. permissible load 
(P level, reference value)

10 mV, 10 

μ

A

Mechanical life

50,000,000 operations min. 
(at a switching frequency of 
36,000 operations/hr)

Electrical life 
(at an ambient 
temperature of 23

°

C)

100,000 operations min. 
(at the rated load with a switching 
frequency of 1,800 operations/hr)

Rated load voltage

24 VDC

Max. load current

50 mA

Leakage current

100 

μ

A max.

Item

RS-485

Communications method 2-wire, half-duplex

Synchronization method

Start-stop synchronization

Baud rate

1,200/2,400/4,800/9,600/19,200 bps

Transmission code

ASCII

Commu-
nications

Reading/
Writing to the 
K3GN

Read/write comparative set values, 
read/write scaling values, enable/
disable the writing of data through 
communications, forced-zero control, 
and other data.

Item

0 to 

20 mA

4 to 

20 mA

0 to 5 V 1 to 5 V

0 to 

10 V

Permissible load 
impedance

500 

Ω

 max.

5 k

Ω

 min. 

Resolution

Approx. 10,000

Output error

±0.5% full scale

±0.5 full scale.
±0.15 V at 1 V or less 
(no output for 0 or less)

Summary of Contents for K3GN

Page 1: ...rrent PNP 2 Output Type C 2 relay contact outputs SPST NO C FLK 2 relay contact outputs SPST NO and RS 485 C L1 2 relay contact outputs SPST NO and DC current 0 to 20 mA 4 to 20 mA C L2 2 relay contac...

Page 2: ...VDC RS 485 K3GN PDC FLK 24 VDC 3 transistor outputs PNP open collector None K3GN PDT2 24 VDC RS 485 K3GN PDT2 FLK 24 VDC Item K3GN ND With DC voltage DC current and NPN input K3GN PD With DC voltage D...

Page 3: ...sistor outputs 150 m s2 three times each in 3 axes 6 directions Models with contact outputs 100 m s2 three times each in 3 axes 6 directions Weight Approx 100 g Main Unit only Degree of protection Fro...

Page 4: ...23 C 100 000 operations min at the rated load with a switching frequency of 1 800 operations hr Rated load voltage 24 VDC Max load current 50 mA Leakage current 100 A max Item RS 485 Communications me...

Page 5: ...mmunications writing is enabled and is out when it is disabled 3 Level indicator Displays the current level that the K3GN is in See below for details 4 Level Key Used to change the level 5 Mode Key Us...

Page 6: ...nergized Relays K3GN NDC 400 24 VDC K3GN NDC FLK 400 24 VDC K3GN NDC L1 400 24 VDC K3GN NDC L2 400 24 VDC Relation between Output Type and Relay Output Operation Hysteresis Set value Measurement value...

Page 7: ...5 VDC 1 to 5 VDC 0 to 10 VDC I K L Outputs Outputs relay or transistor outputs There is also a PASS output for models with transistor outputs I J K L B A 7 8 7 8 C 1 2 3 1 2 3 A 9 10 11 12 9 10 11 12...

Page 8: ...EEPROM Analog input terminal Pulse Control input terminal Control input circuit A D conversion circuit Waveform rectification circuit Micro computer Note 1 Transistor output models only 2 Linear outpu...

Page 9: ...r example when adjusting reference values Note This function can be used only when forced zero operation protection is released Changing the Display Color The color of the value displayed can be set t...

Page 10: ...erproof when gang mounted 7 mm 3 6 mm Main Display Character Size The K3GN uses M3 terminals A terminal cover is provided Panel Cutout Dimensions K3GN For installation insert the K3GN panel into the r...

Page 11: ...e surface of the soup is detected with an ultrasonic sensor and based on this distance the K3GN displays the remaining quantity When the remaining quantity of soup decreases to less than 20 the K3GN l...

Page 12: ...of the product may be damaged by organic solvents thinner benzine etc strong alkaline materials and strong acid materials 6 Avoid storing in high humidity or in a corrosive gas environment including d...

Page 13: ...hen setting up the control system 10 Install an external switch or circuit breaker and label them clearly so that the operator can quickly turn OFF the power 11 Ensure that the rated voltage is achiev...

Page 14: ...PAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s ap...

Reviews: