F-14

1/32 DIN Digital Panel Meter 

K3GN

Dimensions

Note: All units are in millimeters unless otherwise indicated.

Wiring Precautions 

• Wire the power supply with the correct polarity. Wiring with incorrect polarity may result in damage or burning.
• Wire the terminals using crimp terminals.
• Tighten terminal screws to a torque of approx. 0.5 N·m.
• Wire signal lines and power lines separately to reduce the influence of noise.

Wiring

Power Supply

• Input 24 VDC to terminals 1 and 2.

• Use M3 crimp terminals of the type shown below.

Measurement Input

 The following table shows the relation between input ranges and 

input terminals.

/ZERO

ZERO

OUT1

OUT2

SV

HOLD

CMW

T

K3GN

3

80

22

44.8

48

24

35

Separate mounting

Gang mounting

22.2

+0.3
0

22.2

+0.3
0

45

+0.6
0

(48 

×

 No. of Panels 

 2.5)

+1.0
0

40 min.

The products cannot be 
made waterproof when 
gang-mounted.

7 mm

3.6 mm

Main Display Character Size

The K3GN uses M3 terminals. A terminal 
cover is provided.

Panel Cutout Dimensions

K3GN

• For installation, insert the K3GN 

panel into the rectangular hole, 
insert the adaptor from the rear, and 
push it in to reduce the gap between 
the panel surface and the adaptor. 
Secure the Unit with the screws. 
For water-proof installation, insert 
the rubber gasket onto the body of 
the K3GN. 

• If multiple mounted Units are used, 

make sure the ambient temperature 
for the K3GN does not exceed the 
specified temperature.

1

2

24 VDC

5.8 mm max.

5.8 mm max.

Input range

Input 

terminals

DC voltage/DC current

4 to 20 mA

E

-

F

1 to 5 V

D

-

E

±

5 V

±

10 V

No-voltage contacts and NPN open collector
(Models with NPN inputs)

B

-

C

No-voltage contacts and PNP open collector
(Models with PNP inputs)

A

-

C

Be sure to read the Precautions for Correct Use and other information required when using the K3GN in the 
following user’s manual.
K3GN Digital Panel Meter User’s Manual (Cat.No. N102)

Summary of Contents for K3GN

Page 1: ...rrent PNP 2 Output Type C 2 relay contact outputs SPST NO C FLK 2 relay contact outputs SPST NO and RS 485 C L1 2 relay contact outputs SPST NO and DC current 0 to 20 mA 4 to 20 mA C L2 2 relay contac...

Page 2: ...VDC RS 485 K3GN PDC FLK 24 VDC 3 transistor outputs PNP open collector None K3GN PDT2 24 VDC RS 485 K3GN PDT2 FLK 24 VDC Item K3GN ND With DC voltage DC current and NPN input K3GN PD With DC voltage D...

Page 3: ...sistor outputs 150 m s2 three times each in 3 axes 6 directions Models with contact outputs 100 m s2 three times each in 3 axes 6 directions Weight Approx 100 g Main Unit only Degree of protection Fro...

Page 4: ...23 C 100 000 operations min at the rated load with a switching frequency of 1 800 operations hr Rated load voltage 24 VDC Max load current 50 mA Leakage current 100 A max Item RS 485 Communications me...

Page 5: ...mmunications writing is enabled and is out when it is disabled 3 Level indicator Displays the current level that the K3GN is in See below for details 4 Level Key Used to change the level 5 Mode Key Us...

Page 6: ...nergized Relays K3GN NDC 400 24 VDC K3GN NDC FLK 400 24 VDC K3GN NDC L1 400 24 VDC K3GN NDC L2 400 24 VDC Relation between Output Type and Relay Output Operation Hysteresis Set value Measurement value...

Page 7: ...5 VDC 1 to 5 VDC 0 to 10 VDC I K L Outputs Outputs relay or transistor outputs There is also a PASS output for models with transistor outputs I J K L B A 7 8 7 8 C 1 2 3 1 2 3 A 9 10 11 12 9 10 11 12...

Page 8: ...EEPROM Analog input terminal Pulse Control input terminal Control input circuit A D conversion circuit Waveform rectification circuit Micro computer Note 1 Transistor output models only 2 Linear outpu...

Page 9: ...r example when adjusting reference values Note This function can be used only when forced zero operation protection is released Changing the Display Color The color of the value displayed can be set t...

Page 10: ...erproof when gang mounted 7 mm 3 6 mm Main Display Character Size The K3GN uses M3 terminals A terminal cover is provided Panel Cutout Dimensions K3GN For installation insert the K3GN panel into the r...

Page 11: ...e surface of the soup is detected with an ultrasonic sensor and based on this distance the K3GN displays the remaining quantity When the remaining quantity of soup decreases to less than 20 the K3GN l...

Page 12: ...of the product may be damaged by organic solvents thinner benzine etc strong alkaline materials and strong acid materials 6 Avoid storing in high humidity or in a corrosive gas environment including d...

Page 13: ...hen setting up the control system 10 Install an external switch or circuit breaker and label them clearly so that the operator can quickly turn OFF the power 11 Ensure that the rated voltage is achiev...

Page 14: ...PAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s ap...

Reviews: